- AF140-30-00-13
The ABB AF140-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. Its coil accepts a rated control circuit voltage of 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The main circuit is rated 690 V and 50/60 Hz, with AC-3 ratings of 140 A at 415 V and 75 kW at 415 V. Conventional free-air thermal current is 200 A per IEC 60947-4-1 at 40 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Mechanical durability is 5 million operating cycles. The contactor uses double-clamp terminals and is classified as ETIM EC000066.
- AF140-30-00-14
The ABB AF140-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 200 A at 690 V and 40 °C, and 160 A at 690 V and 70 °C. AC-3 ratings include 140 A at 415 V and 55 °C, 130 A at 500 V and 55 °C, and 80 A at 690 V and 55 °C. AC-3 rated operational power includes 75 kW at 415 V and 90 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-00-31
The ABB AF140-30-00-31 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-00-32
ABB AF140-30-00-32 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 at an open-contactor ambient of 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 138.5 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-33
The ABB AF140-30-00-33 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Corresponding AC-3 rated operational power is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF140-30-00-34
The ABB AF140-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 130 A at 500 V, and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V, 90 kW at 440 V and 500 V, 75 kW at 690 V and 380/400 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 142.5 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-42
The ABB AF140-30-00-42 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 130 A at 500 V, and 80 A at 690 V, all at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AF140-30-00-43
The ABB AF140-30-00-43 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 200 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 140 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 130 A at 500 V; and 80 A at 690 V. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V and 500 V, 75 kW at 690 V, and 37 kW at 220/230/240 V.