- AF40-30-22-12
The ABB AF40-30-22-12 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 55 mm wide, 144 mm deep, and 125.5 mm high, and weighs 1.02 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Rated operational current AC-3 is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-22-13
The ABB AF40-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 55 mm wide, 144 mm deep, and 125.5 mm high, and weighs 1 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-3 ratings include 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V; corresponding AC-3 power is 18.5 kW at 400 V and 22 kW at 415 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-30-22-14
The ABB AF40-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 55 mm wide, 144 mm deep, and 125.5 mm high, weighing 1 kg. The control circuit accepts 250 to 500 V at 50 or 60 Hz, and 250 to 500 V DC. Rated operational current AC-3 is 40 A at 415 V and 60 °C, 35 A at 500 V, and 25 A at 690 V. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 415 V. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-40-00-11
ABB AF40-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and 50/60 Hz on both control and main circuits. Per IEC 60947-4-1, conventional free-air thermal current Ith is 105 A at 40 °C for open contactors. Rated operational current AC-1 is 70 A at 690 V and 40 °C, 60 A at 60 °C, and 50 A at 70 °C. AC-3 ratings include 40 A at 415 V and 440 V, both at 60 °C. Rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA; impulse withstand is 6 kV. Dimensions are 70 mm wide, 113.5 mm deep, and 125.5 mm high, weighing 1.21 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF40-40-00-12
The ABB AF40-40-00-12 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, weighing 1.21 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 40 A at 415 V, 440 V, and 380/400 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-40-00-13
The ABB AF40-40-00-13 is a 4-pole AC/DC operated contactor with four normally open main contacts and no auxiliary contacts. It is identified by manufacturer ID 1SBL347201R1300. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 40 A at 415 V, 440 V, and 380/400 V at 60 °C, and 25 A at 690 V at 60 °C. Rated operational power AC-3 is 22 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 70 mm wide, 113.5 mm deep, and 125.5 mm high, with a net weight of 1.27 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-40-00-13LU
ABB AF40-40-00-13LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, and weighs 1.27 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 degrees C. AC-3 rated operational current is 40 A at 415 V and 440 V, 35 A at 500 V, and 25 A at 690 V, all at 60 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF40-40-00-14
The ABB AF40-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, weighing 1.16 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 105 A according to IEC 60947-4-1 for open contactors at 40 degrees C. AC-3 rated operational current is 40 A at 415 V and 60 degrees C, and rated operational power is 22 kW at 415 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.