- AFS116-30-12-12
ABB AFS116-30-12-12 AC contactor, manufacturer ID 1SFL427081R1212. Main circuit rated 690 V at 50/60 Hz, with 3 NO main contacts, 1 NO auxiliary contact, and 2 NC auxiliary contacts. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C; 110 A at 500 V; and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions: 90 mm wide, 126 mm deep, 150 mm high; net weight 1.55 kg.
- AFS116-30-12-13
The ABB AFS116-30-12-13 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, and 55 kW at 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AFS116-30-12-14
The ABB AFS116-30-12-14 is a three-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 116 A at 415 V and 60 °C. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC.
- AFS116-30-12-33
The ABB AFS116-30-12-33 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V. The control circuit voltage range is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Coil terminals are IP20 and main terminals IP00 per IEC 60529.
- AFS116-30-12-34
The ABB AFS116-30-12-34 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AFS116-30-12B-12
The ABB AFS116-30-12B-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AFS116-30-12B-13
The ABB AFS116-30-12B-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AFS116-30-12B-14
The ABB AFS116-30-12B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 116 A at 415 V and 55 kW at 415 V, both at 60 °C. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.