- AFS116-30-12-33
The ABB AFS116-30-12-33 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V. The control circuit voltage range is 100 to 250 V for 50 Hz, 60 Hz, and DC operation. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Coil terminals are IP20 and main terminals IP00 per IEC 60529.
- AFS116-30-12-34
The ABB AFS116-30-12-34 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg.
- AFS116-30-12B-12
The ABB AFS116-30-12B-12 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 440 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AFS116-30-12B-13
The ABB AFS116-30-12B-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AFS116-30-12B-14
The ABB AFS116-30-12B-14 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 116 A at 415 V and 55 kW at 415 V, both at 60 °C. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. Coil control voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AFS116-30-12B-33
The ABB AFS116-30-12B-33 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It carries one normally open and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 60 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; weight is 1.3 kg. Manufacturer ID: 1SFL427082R3312.
- AFS116-30-12B-34
The ABB AFS116-30-12B-34 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and an impulse withstand voltage of 8 kV. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 116 A at 415 V and 60 °C, and rated operational power is 55 kW at 415 V. Mechanical durability is 5 million operations. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, weighing 1.3 kg.
- AFS12-30-22-11
The ABB AFS12-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 110.5 mm deep, and 86 mm high, and weighs 0.32 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 12 A at 415 V and 440 V, 12.5 A at 500 V, and 9 A at 690 V, at 60 °C. Rated operational power AC-3 is 5.5 kW at 400 V and 7.5 kW at 500 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.