- UA110-30-00-86
The ABB UA110-30-00-86 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It has a rated operational voltage of 1000 V in the main circuit and a rated frequency of 50/60 Hz. The conventional free-air thermal current is 160 A according to IEC 60947-4-1 at an open contactor ambient temperature of 40 °C. Rated operational power for AC-6b at 400/415 V, 40 °C, 50/60 Hz is 75 kvar. The contactor measures 90 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg. Maximum mechanical switching frequency is 3600 cycles per hour, and mechanical durability is 10 million operations.
- UA110-30-00-88
The ABB UA110-30-00-88 is a three-phase AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V at 40 °C and 55 °C, 35 kvar at 230/240 V at 70 °C, and 75 kvar at 400/415 V at 40 °C. Maximum breaking capacity is 1160 A at 440 V and 800 A at 690 V. Dimensions are 90 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA110-30-11-42
The ABB UA110-30-11-42 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It has a rated operational voltage of 1000 V in the main circuit and operates at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 230/240 V and 55 °C, and 35 kvar at 230/240 V and 70 °C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA110-30-11-80
The ABB UA110-30-11-80 is a three-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 102 mm wide, 123.5 mm deep, and 148 mm high, and weighs 1.8 kg. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Mechanical durability is 10 million operations, with maximum mechanical switching frequency of 3600 cycles per hour.
- UA110-30-11-83
The ABB UA110-30-11-83 is a three-phase AC contactor for capacitor duty, identified by manufacturer ID 1SFL451022R8311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz, with a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational power in AC-6b is 40 kvar at 230/240 V, 50/60 Hz, 40 degrees C. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA110-30-11-84
ABB UA110-30-11-84 is a 3-phase AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 230/240 V and 55 °C, 35 kvar at 230/240 V and 70 °C, and 75 kvar at 400/415 V and 40 °C, all at 50/60 Hz. Rated insulation voltage is 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V per UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high; net weight is 1.8 kg.
- UA110-30-11-85
The ABB UA110-30-11-85 is a three-phase AC contactor for capacitor duty, identified by manufacturer ID 1SFL451022R8511. It has three normally open main contacts, no normally closed main contacts, and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 40 kvar at 55 °C, and 35 kvar at 70 °C, all at 50/60 Hz. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.
- UA110-30-11-86
The ABB UA110-30-11-86 is a three-pole AC contactor intended for capacitor switching. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. The main circuit is rated 1000 V with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational power in AC-6b is 40 kvar at 230/240 V and 40 °C, 50/60 Hz. Rated insulation voltage is 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 600 V according to UL/CSA. Rated impulse withstand voltage is 8 kV. Mechanical durability is 10 million operations. Dimensions are 102 mm wide, 123.5 mm deep, and 148 mm high, with a net weight of 1.8 kg.