- CA4-13N
The ABB CA4-13N is a front-mount auxiliary contact block with one normally open (NO) and three normally closed (NC) contacts. It has screw terminals and measures 43 mm wide, 39.5 mm deep, and 43 mm high, weighing 0.055 kg. The auxiliary circuit is rated 690 V, 50/60 Hz, with a conventional free-air thermal current of 16 A at 40 °C per IEC 60947-5-1. Rated operational currents include AC-15: 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V; DC-13: 6 A/144 W at 24 V, 2.8 A/134 W at 48 V, and 0.55 A/60 W at 110 V. It conforms to IEC/EN 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1-14. Auxiliary terminals offer IP20 protection. Maximum switching frequencies are 1200 cycles per hour (AC-15) and 900 cycles per hour (DC-13).
- CA4-13NK
ABB CA4-13NK is a 4-pole front-mounted auxiliary contact block with push-in spring terminals, providing 1 N.O. and 3 N.C. instantaneous contacts. It measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Suitable for NF22E, NFZ22E, NF31E, NFZ31E, NF40E, NFZ40E, NFC22E, NFC31E, NFC40E, NFZB22E, NFB22E, NFZB31E, NFB31E, NFZB40E, and NFB40E.
- CA4-20
ABB CA4-20 auxiliary contact block, manufacturer ID 1SBN010110R1020. It provides 2 auxiliary contacts NO and 0 NC. Dimensions are 43 mm width, 19.9 mm depth, 23.6 mm height, and 0.024 kg net weight. The auxiliary circuit is rated 690 V, 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 2 A at 500 V and 690 V, 6 A at 24/127 V, 4 A at 220/240 V, and 3 A at 400/440 V. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Screw terminals, auxiliary terminals IP20, wire stripping length 10 mm.
- CA4-22E
ABB CA4-22E auxiliary contact block with 2 normally open and 2 normally closed auxiliary contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated impulse withstand voltage is 6 kV; rated insulation voltage is 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA. Screw terminals accept rigid solid or stranded conductors from 1 to 2.5 mm². Auxiliary terminals have IP20 protection according to IEC 60529. Dimensions are 43 mm width, 39.5 mm depth, 43 mm height; net weight 0.055 kg. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-22EK
The ABB CA4-22EK is a front-mounted auxiliary contact block with two normally open (NO) and two normally closed (NC) contacts. It uses push-in spring terminals with a wire stripping length of 10 mm. The auxiliary circuit is rated 690 V and 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. It is suitable for AF09 through AF96 and AFC09 through AFC30 series contactors. The block measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-22ERT
The ABB CA4-22ERT is a 4-pole front-mounted auxiliary contact block with 2 NO and 2 NC auxiliary contacts. It measures 45 mm wide, 39.8 mm deep, and 43 mm high, and weighs 0.05 kg. Terminals are ring-tongue type, with a tightening torque of 11 in·lb for the auxiliary circuit per UL/CSA. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A at 40 °C per IEC 60947-5-1, rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA, and rated impulse withstand voltage 6 kV. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529.
- CA4-22M
ABB CA4-22M front-mount auxiliary contact block with screw terminals, 2 NO and 2 NC auxiliary contacts. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current Ith is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage Ui is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage Uimp is 6 kV. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14. Auxiliary terminals IP20. Net dimensions 43 mm x 39.5 mm x 43 mm; net weight 0.055 kg.
- CA4-22MK
The ABB CA4-22MK is a 4-pole front-mounted auxiliary contact block with 2 N.O. and 2 N.C. instantaneous contacts and Push-In Spring terminals. It measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.