- CA4-22MK
The ABB CA4-22MK is a 4-pole front-mounted auxiliary contact block with 2 N.O. and 2 N.C. instantaneous contacts and Push-In Spring terminals. It measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V according to IEC 60947-5-1 and 600 V according to UL/CSA, and rated impulse withstand voltage 6 kV. Auxiliary terminals are IP20 according to IEC 60529, IEC 60947-1, and EN 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-22MRT
The ABB CA4-22MRT is an auxiliary contact block with two normally open (NO) and two normally closed (NC) auxiliary contacts. It measures 45 mm wide, 39.8 mm deep, and 43 mm high, and weighs 0.05 kg. Rated operational voltage for the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA. Rated impulse withstand voltage is 6 kV. Terminals are ring-tongue type, IP20. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10.
- CA4-22N
The ABB CA4-22N is an auxiliary contact block with 2 normally open (NO) and 2 normally closed (NC) auxiliary contacts. It measures 43 mm wide, 39.5 mm deep, and 43 mm high, and weighs 0.055 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.
- CA4-22NK
The ABB CA4-22NK is a four-pole front-mounted auxiliary contact block with push-in spring terminals, providing two normally open (N.O.) and two normally closed (N.C.) instantaneous contacts. It measures 43 mm wide, 39.5 mm deep, and 45 mm high, and weighs 0.05 kg. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C, rated insulation voltage 690 V per IEC 60947-5-1 and 600 V per UL/CSA, and rated impulse withstand voltage 6 kV. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Applicable standards are IEC/EN 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1-14.
- CA4-22NRT
The ABB CA4-22NRT is a front-mounted auxiliary contact block with 2 NO and 2 NC contacts, identified by manufacturer ID 1SBN010142R1222. It uses ring-tongue terminals with a tightening torque of 11 in·lb for the auxiliary circuit. The auxiliary circuit is rated 690 V at 50/60 Hz, with conventional free-air thermal current 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Dimensions are 45 mm width, 39.8 mm depth, 43 mm height, 0.05 kg. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10.
- CA4-22U
The ABB CA4-22U is a front-mount auxiliary contact block with two normally open (NO) and two normally closed (NC) contacts. It is identified by manufacturer ID 1SBN010140R1322. The auxiliary circuit is rated for 690 V and 50/60 Hz, with a conventional free-air thermal current of 16 A according to IEC 60947-5-1 at 40 °C. Rated operational current AC-15 is 6 A at 24/127 V, 4 A at 220/240 V, 3 A at 400/440 V, and 2 A at 500 V and 690 V. DC-13 ratings include 6 A / 144 W at 24 V and 0.15 A at 400 V. It conforms to IEC/EN 60947-5-1, UL 60947-5-1, and CSA C22.2 No. 60947-5-1-14. Dimensions are 43 mm width, 39.5 mm depth, 43 mm height, and 0.055 kg weight. Auxiliary terminals provide IP20 protection.
- CA4-22URT
The ABB CA4-22URT is an auxiliary contact block with two normally open (NO) and two normally closed (NC) auxiliary contacts. It measures 45 mm wide, 39.8 mm deep, and 43 mm high, and weighs 0.055 kg. It is suitable for AF09B, AF09ZB, AF12B, AF12ZB, AF16B, and AF16ZB. The block uses ring-tongue terminals and provides IP20 protection on auxiliary terminals according to IEC 60529, IEC 60947-1, and EN 60529. It is rated 690 V in the auxiliary circuit at 50/60 Hz, with a conventional free-air thermal current of 16 A at 40 °C per IEC 60947-5-1. Standards: IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-10.
- CA4-31E
ABB CA4-31E auxiliary contact block with 3 N.O. and 1 N.C. instantaneous contacts and screw terminals. Rated operational voltage of the auxiliary circuit is 690 V at 50/60 Hz. Conventional free-air thermal current is 16 A according to IEC 60947-5-1 at 40 °C. Rated insulation voltage is 690 V per IEC 60947-5-1 and 600 V per UL/CSA; rated impulse withstand voltage is 6 kV. Maximum mechanical switching frequency is 3600 cycles per hour. Auxiliary terminals are IP20 per IEC 60529, IEC 60947-1, and EN 60529. Dimensions are 43 mm width, 39.5 mm depth, 43 mm height; net weight 0.055 kg. Standards: IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1-14.