- XLP2-6BC
ABB XLP2-6BC fuse type isolating switch, manufacturer ID 1SEP101892R0002. Three-pole (3P) baseplate-mounted unit with front cover 3P handle, cable clamp terminals, and DIN NH2 fuse system. Rated current 400 A; rated operational voltage 500 V AC and 690 V AC; rated frequency 50/60 Hz; rated impulse withstand voltage 8 kV. Rated operational current AC-21B is 315 A at 690 V; AC-22B is 400 A at 500 V and 400 A at 800 V. Rated conditional short-circuit current is 50 kA rms at 690 V. Power loss at rated load 13 W. Degree of protection IP30. Dimensions 210 mm wide, 290 mm high, 130 mm deep; net weight 3.02 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring not included.
- XLP2-A60/120-A-above
ABB XLP2-A60/120-A-above fuse type isolating switch, manufacturer ID 1SEP102285R0001. Three-pole fuse switch disconnector for a 60 mm busbar system, rated current 400 A, rated operational voltage 500 V AC / 690 V AC, rated frequency 50/60 Hz on the main circuit. Rated impulse withstand voltage 8 kV. Rated conditional short-circuit current 50 kA rms at 690 V. Rated operational current 315 A at 690 V AC-21B and 400 A at 500 V AC-22B. NH2 DIN fuse size, lug terminals, front cover 3P handle, IP30 protection. Power loss 13 W at rated load. Net dimensions 210 mm width, 290 mm height, 210 mm depth; net weight 4.6 kg. Standards IEC60947-3 and GB/T14048.3.
- XLP2-A60/120-B-below
ABB XLP2-A60/120-B-below fuse type isolating switch, manufacturer ID 1SEP102286R0001. Three-pole device rated 400 A, 50/60 Hz main circuit, with 8 kV rated impulse withstand voltage. Rated operational current is 315 A at 690 V AC-21B and 400 A at 500 V AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V. Accepts NH2 DIN fuse system fuses. Front cover 3P handle, 60 mm busbar system mounting. Power loss at rated load 13 W. Dimensions 210 mm wide, 290 mm high, 210 mm deep; net weight 4.6 kg. Degree of protection IP30. No electronic fuse monitoring.
- XLP2-S&J-6M12
ABB XLP2-S&J-6M12 is an industrial catalog item. Key specifications include Degree of Protection: IP30, Product Net Width: 210 mm, Product Net Height: 290 mm, and Product Net Depth / Length: 130 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- XLP3
The ABB XLP3 is a 3-pole fuse type isolating switch with a rated current of 630 A. It uses NH3 DIN fuse system fuses and is mounted on a baseplate with a front cover 3P handle. Rated operational voltage is 500 V AC and 690 V AC, with rated frequency 50/60 Hz on the main circuit. Rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current is 630 A at 500 V AC-22B and 500 A at 690 V AC-21B. Power loss is 24 W at rated load. Degree of protection is IP30. Dimensions are 250 mm wide, 330 mm high, and 142 mm deep; net weight is 4.04 kg. Standards: IEC60947-3 and GB/T14048.3.
- XLP3-1P
The ABB XLP3-1P is a single-pole fuse type isolating switch, identified by manufacturer ID 1SEP600126R0001. It accepts NH3 fuses in a DIN fuse system and mounts on a baseplate with a front cover handle for 1P operation. Rated current is 630 A at a main circuit frequency of 50/60 Hz. Rated operational current is 500 A at 690 V in AC-21B and 630 A at 500 V in AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated impulse withstand voltage is 8 kV. Power loss at rated load is 24 W. Dimensions are 89.5 mm wide, 142 mm high, and 330 mm deep; net weight is 1.87 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP3-1P-2BC
ABB XLP3-1P-2BC fuse type isolating switch, 1-pole, rated current 630 A, rated operational voltage 220 V DC, 500 V AC, 690 V AC, rated frequency 50/60 Hz. Rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Rated operational currents: AC-21B 500 A at 690 V, AC-22B 630 A at 500 V, DC-22B 630 A at 220 V. Fuse size NH3, DIN fuse system, cable clamp terminals, baseplate mounting, front cover 1P handle. Power loss 24 W at rated load. Degree of protection IP30. Dimensions 89.5 mm wide, 142 mm high, 330 mm deep; net weight 2.04 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring not included.
- XLP3-2P
ABB XLP3-2P fuse type isolating switch, manufacturer ID 1SEP600127R0001. This two-pole fuse switch disconnector is rated 630 A and accepts NH3 fuses in a DIN fuse system. Main circuit rated frequency is 50/60 Hz, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current is 500 A at 690 V in AC-21B and 630 A at 500 V in AC-22B. Power loss at rated load is 24 W. The front cover 2P handle and baseplate mounting suit fixed installation. Dimensions are 179 mm wide, 142 mm high, and 330 mm deep; net weight is 3.95 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.