- XLP3-1P
The ABB XLP3-1P is a single-pole fuse type isolating switch, identified by manufacturer ID 1SEP600126R0001. It accepts NH3 fuses in a DIN fuse system and mounts on a baseplate with a front cover handle for 1P operation. Rated current is 630 A at a main circuit frequency of 50/60 Hz. Rated operational current is 500 A at 690 V in AC-21B and 630 A at 500 V in AC-22B. Rated conditional short-circuit current is 50 kA rms at 690 V, and rated impulse withstand voltage is 8 kV. Power loss at rated load is 24 W. Dimensions are 89.5 mm wide, 142 mm high, and 330 mm deep; net weight is 1.87 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP3-1P-2BC
ABB XLP3-1P-2BC fuse type isolating switch, 1-pole, rated current 630 A, rated operational voltage 220 V DC, 500 V AC, 690 V AC, rated frequency 50/60 Hz. Rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Rated operational currents: AC-21B 500 A at 690 V, AC-22B 630 A at 500 V, DC-22B 630 A at 220 V. Fuse size NH3, DIN fuse system, cable clamp terminals, baseplate mounting, front cover 1P handle. Power loss 24 W at rated load. Degree of protection IP30. Dimensions 89.5 mm wide, 142 mm high, 330 mm deep; net weight 2.04 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring not included.
- XLP3-2P
ABB XLP3-2P fuse type isolating switch, manufacturer ID 1SEP600127R0001. This two-pole fuse switch disconnector is rated 630 A and accepts NH3 fuses in a DIN fuse system. Main circuit rated frequency is 50/60 Hz, rated impulse withstand voltage is 8 kV, and rated conditional short-circuit current is 50 kA rms at 690 V. Rated operational current is 500 A at 690 V in AC-21B and 630 A at 500 V in AC-22B. Power loss at rated load is 24 W. The front cover 2P handle and baseplate mounting suit fixed installation. Dimensions are 179 mm wide, 142 mm high, and 330 mm deep; net weight is 3.95 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP3-2P-4BC
ABB fuse type isolating switch, model XLP3-2P-4BC, manufacturer ID 1SEP600127R0002. Two-pole (2P) unit with NH3 DIN fuse system, baseplate mounting, and front cover 2P handle. Rated current 630 A; rated operational currents include 500 A at 690 V AC (AC-21B), 630 A at 500 V AC (AC-22B), and 630 A at 440 V DC (DC-22B). Rated operational and rated voltages are 440 V DC, 500 V AC, and 690 V AC. Rated frequency 50/60 Hz. Rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Power loss 24 W at rated load. Cable clamp terminals. Degree of protection IP30. Dimensions 179 mm wide, 142 mm high, 330 mm deep; net weight 4.3 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring not included.
- XLP3-4P
The ABB XLP3-4P is a 4-pole fuse type isolating switch, manufacturer ID 1SEP600128R0001. It uses NH3 DIN fuses and mounts on a baseplate with a front cover 4P handle. The main circuit is rated 630 A at 500 V AC, 50/60 Hz, with a rated operational current AC-22B of 630 A at 500 V and a rated impulse withstand voltage of 8 kV. Rated conditional short-circuit current is 50 kA rms at 690 V. Power loss is 24 W at rated load. Dimensions are 339 mm wide, 142 mm high, and 330 mm deep; net weight is 6.74 kg. Degree of protection is IP30. Electronic fuse monitoring is not included.
- XLP3-4P-8BC
ABB XLP3-4P-8BC fuse type isolating switch, manufacturer ID 1SEP600128R0002. Four-pole (4P) fuse switch disconnector for DIN NH3 fuse links, baseplate mounting, front cover 4P handle. Rated current 630 A; rated operational voltage 500 V AC; rated operational current AC-22B 630 A at 500 V; main circuit rated frequency 50/60 Hz; rated impulse withstand voltage 8 kV; rated conditional short-circuit current 50 kA rms at 690 V. Power loss at rated load 24 W. Degree of protection IP30. Dimensions 339 mm wide, 142 mm high, 330 mm deep; net weight 7.43 kg. Electronic fuse monitoring: no.
- XLP3-6BC
The ABB XLP3-6BC is a fuse type isolating switch, identified by manufacturer ID 1SEP101975R0002. It is a 3-pole device with a rated current of 630 A and a rated frequency of 50/60 Hz for the main circuit. Rated operational current is 500 A at 690 V in AC-21B and 630 A at 500 V in AC-22B. The rated conditional short-circuit current is 50 kA rms at 690 V, and the rated impulse withstand voltage is 8 kV. It accepts NH3 fuses in the DIN system and mounts on a baseplate with a front cover 3P handle. Power loss is 24 W at rated load. Dimensions are 250 mm wide, 330 mm high, and 142 mm deep, with a net weight of 4.75 kg and IP30 protection. Electronic fuse monitoring is not included.
- XLP3-A60/120-A-above
ABB fuse type isolating switch, display model XLP3-A60/120-A-above, manufacturer ID 1SEP102287R0001. Three-pole (3P) fuse switch disconnector for a 60 mm busbar system, with front cover 3P handle and lug terminals. Rated current 630 A; rated operational voltage 500 V AC and 690 V AC; rated frequency 50/60 Hz. Rated operational current AC-21B is 500 A at 690 V and AC-22B is 630 A at 500 V. Rated conditional short-circuit current is 50 kA rms at 690 V; rated impulse withstand voltage 8 kV. Fuse size NH3, DIN fuse system. Power loss 24 W at rated load. Degree of protection IP30. Dimensions 250 mm wide, 330 mm high, 210 mm deep; net weight 6.3 kg. Standards IEC60947-3 and GB/T14048.3. Electronic fuse monitoring: No.