- AF26B-22-00RT-14
The ABB AF26B-22-00RT-14 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It has ring-tongue terminals and measures 45 mm wide, 77 mm deep, and 86 mm high, weighing 0.39 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. The control circuit is rated 250 to 500 V at 50 Hz, 60 Hz, and DC operation. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- AF26B-30-00-14
ABB AF26B-30-00-14 is a 3-pole AC contactor, manufacturer ID 1SBL237061R1400. It has 3 main contacts NO and no auxiliary contacts. Main circuit rated operational voltage is 690 V; control and main circuit rated frequency is 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Dimensions are 45 mm width, 86 mm depth, 86 mm height; net weight 0.37 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF26B-30-00K-14
The ABB AF26B-30-00K-14 is a 3-pole AC contactor with push-in spring terminals and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 26 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 23 A at 500 V, and 17 A at 690 V, all at 60 °C. Rated operational power AC-3 is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26B-30-00RT-14
The ABB AF26B-30-00RT-14 is a 3-pole AC contactor with ring-tongue terminals and no auxiliary contacts (0 NO, 0 NC). It measures 45 mm wide, 86 mm deep, and 86 mm high, weighing 0.36 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and an insulation voltage of 690 V per IEC 60947-4-1 and 600 V per UL/CSA. AC-3 rated operational power is 11 kW at 380/400 V and 415 V, 15 kW at 440 V, 500 V, and 690 V, and 6.5 kW at 220/230/240 V, all at 60 °C. Control circuit voltage is 250 to 500 V at 50/60 Hz and DC. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, and IEC 61373.
- AF26B-40-00-14
The ABB AF26B-40-00-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1, and CSA C22.2 No. 60947-4-1.
- AF26B-40-00RT-14
The ABB AF26B-40-00RT-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has ring-tongue terminals and measures 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.39 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. The control circuit voltage is 250 to 500 V at 50 Hz and 60 Hz, and 250 to 500 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or with two M4 screws placed diagonally.
- AF26Z-22-00-20
The ABB AF26Z-22-00-20 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF26Z-22-00-21
The ABB AF26Z-22-00-21 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-3 is 22 A at 380/400 V and 60 degrees C, and rated operational power AC-3 is 11 kW at 400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.