- AF26B-40-00RT-14
The ABB AF26B-40-00RT-14 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It has ring-tongue terminals and measures 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.39 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. The control circuit voltage is 250 to 500 V at 50 Hz and 60 Hz, and 250 to 500 V DC. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715, or with two M4 screws placed diagonally.
- AF26Z-22-00-20
The ABB AF26Z-22-00-20 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C, 40 A at 60 °C, and 32 A at 70 °C. Rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF26Z-22-00-21
The ABB AF26Z-22-00-21 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Rated operational current AC-3 is 22 A at 380/400 V and 60 degrees C, and rated operational power AC-3 is 11 kW at 400 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26Z-22-00-22
The ABB AF26Z-22-00-22 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. The control circuit operates at 48 to 130 V at 50 Hz, 60 Hz, or DC. Screw terminals accept main circuit conductors from 1.5 to 16 mm². DIN rail mounting is TH35-15 or TH35-7.5 according to IEC 60715. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.4 kg.
- AF26Z-22-00-23
ABB AF26Z-22-00-23 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF26Z-30-00-20
The ABB AF26Z-30-00-20 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. Rated operational current AC-3 is 26 A at 415 V and 60 °C, and 17 A at 690 V and 60 °C. Rated operational power AC-3 is 11 kW at 400 V and 15 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF26Z-30-00-21
ABB AF26Z-30-00-21 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 45 A at 690 V and 40 °C. Rated operational power AC-3 is 11 kW at 400 V and 15 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF26Z-30-00-22
ABB AF26Z-30-00-22 is an AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current Ith is 50 A at 40 °C. AC-3 ratings include 26 A at 415 V and 60 °C, and rated operational power of 11 kW at 400 V and 15 kW at 440 V. Standards listed are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.