- AF38-30-11-12
The ABB AF38-30-11-12 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 38 A at 415 V and 60 °C, with rated operational power of 18.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38-30-11-13
ABB AF38-30-11-13 AC contactor, manufacturer ID 1SBL297001R1311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 60 °C, 33 A at 500 V, and 24 A at 690 V. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V. Dimensions are 45 mm width, 111.5 mm depth, 86 mm height, 0.35 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-30-11-14
ABB AF38-30-11-14 AC contactor, manufacturer ID 1SBL297001R1411, with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.39 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 24 A at 690 V, both at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38-30-22-11
The ABB AF38-30-22-11 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38-30-22-12
The ABB AF38-30-22-12 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It uses screw terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on two M4 screws placed diagonally (not supplied). Dimensions are 45 mm wide, 119.5 mm deep, and 86 mm high; net weight is 0.36 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Rated operational voltage is 690 V for main and auxiliary circuits, with 50/60 Hz rated frequency. AC-3 rated operational power is 18.5 kW at 400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Rated control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC.
- AF38-30-22-13
ABB AF38-30-22-13 is an AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 38 A at 415 V and 24 A at 690 V, both at 60 °C, with 18.5 kW at 400 V and 22 kW at 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL297001R1322.
- AF38-30-22-14
ABB AF38-30-22-14 AC contactor, manufacturer ID 1SBL297001R1422. It has three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 60 °C, and 24 A at 690 V and 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 690 V. Dimensions are 45 mm wide, 119.5 mm deep, and 86 mm high; net weight 0.4 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-40-00-11
The ABB AF38-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C. AC-1 rated operational current is 55 A at 40 °C, 45 A at 60 °C, and 37 A at 70 °C at 690 V. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.