- AF38-30-22-14
ABB AF38-30-22-14 AC contactor, manufacturer ID 1SBL297001R1422. It has three normally open main contacts, two normally open auxiliary contacts, and two normally closed auxiliary contacts. Rated operational voltage is 690 V for both main and auxiliary circuits, with a rated frequency of 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 60 °C, and 24 A at 690 V and 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 690 V. Dimensions are 45 mm wide, 119.5 mm deep, and 86 mm high; net weight 0.4 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-40-00-11
The ABB AF38-40-00-11 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C. AC-1 rated operational current is 55 A at 40 °C, 45 A at 60 °C, and 37 A at 70 °C at 690 V. AC-3 rated operational power is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38-40-00-12
The ABB AF38-40-00-12 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit frequency of 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 22 A at 380/400 V and 60 °C, and rated operational power AC-3 is 11 kW at 400 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.36 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38-40-00-13
The ABB AF38-40-00-13 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 55 A at 40 °C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38-40-00-13LU
ABB AF38-40-00-13LU is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.36 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Control and main circuit rated frequency is 50/60 Hz. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, and CSA C22.2 No. 60947-4-1.
- AF38-40-00-14
The ABB AF38-40-00-14 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a rated insulation voltage of 690 V according to IEC 60947-4-1, with a rated impulse withstand voltage of 6 kV. Conventional free-air thermal current is 55 A at 40 °C per IEC 60947-4-1. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 °C. Control circuit voltage is 250 to 500 V at 50/60 Hz and 250 to 500 V DC. The contactor measures 45 mm wide, 101 mm deep, and 86 mm high, weighs 0.4 kg, and uses screw terminals. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, and CAN/CSA C22.2 No.60947-4-1.
- AF38-40-00-14LU
The ABB AF38-40-00-14LU is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.4 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Rated frequency is 50/60 Hz for both control and main circuits. Conventional free-air thermal current is 55 A at 40 degrees C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400 V, both at 60 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 508, CSA C22.2 No. 60947-4-1.
- AF38B-22-00-14
The ABB AF38B-22-00-14 is an AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.41 kg. The main circuit is rated 690 V, with a rated impulse withstand voltage of 6 kV and an insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. The control circuit operates at 250 to 500 V for both 50 Hz and 60 Hz, and at 250 to 500 V DC. Rated operational power in AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.