Product Model
GAF300-10-11-72
Material Number
1SFL557025R7211
Manufacturer
ABB
Product ID
84587

Get a Free Quote

Request pricing and availability for GAF300-10-11-72.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
5.5 kg
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current DC-1 (Ie)
(1000 V) 3 Poles in Series, 40 °C 500 A (1000 V) 3 Poles in Series, 55 °C 400 A (1000 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 500 A (220 V) 3 Poles in Series, 55 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (400 V) 3 Poles in Series, 40 °C 500 A (400 V) 3 Poles in Series, 55 °C 400 A (400 V) 3 Poles in Series, 70 °C 325 A (600 V) 3 Poles in Series, 40 °C 500 A (600 V) 3 Poles in Series, 55 °C 400 A (600 V) 3 Poles in Series, 70 °C 325 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Maximum Mechanical Switching Frequency
300 cycles per hour
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
See all specifications

Product Highlights

  1. DC Switching Capacity: Rated operational current DC-1 of 500 A at 40 °C with three poles in series, derating to 400 A at 55 °C and 325 A at 70 °C across 220 V, 400 V, 600 V and 1000 V
  2. Contact Configuration: 1 NO main contact, 1 NO auxiliary contact and 1 NC auxiliary contact
  3. Coil and Control: DC-operated coil rated 20 to 60 V with operating limits of 0.85 x Uc minimum to 1.1 x Uc maximum at up to 70 °C
  4. Mechanical Durability: 5 million operating cycles with a maximum mechanical switching frequency of 300 cycles per hour
  5. Dimensions and Mass: 140 mm width, 180.5 mm depth, 227 mm height and 5.5 kg net weight
GAF300-10-11-72

Product Information

Technical Specifications

Specifications for GAF300-10-11-72

ParameterValue
Product Net Width140 mm
Product Net Depth / Length180.5 mm
Product Net Height227 mm
Product Net Weight5.5 kg
Number of Main Contacts NO1
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
Rated Operational Current DC-1 (Ie)(1000 V) 3 Poles in Series, 40 °C 500 A (1000 V) 3 Poles in Series, 55 °C 400 A (1000 V) 3 Poles in Series, 70 °C 325 A (220 V) 3 Poles in Series, 40 °C 500 A (220 V) 3 Poles in Series, 55 °C 400 A (220 V) 3 Poles in Series, 70 °C 325 A (400 V) 3 Poles in Series, 40 °C 500 A (400 V) 3 Poles in Series, 55 °C 400 A (400 V) 3 Poles in Series, 70 °C 325 A (600 V) 3 Poles in Series, 40 °C 500 A (600 V) 3 Poles in Series, 55 °C 400 A (600 V) 3 Poles in Series, 70 °C 325 A
Rated Insulation Voltage (Ui)acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
ParameterValue
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A Pull-in at Max. Rated Control Circuit Voltage DC 520 V·A
Connecting Capacity Main CircuitBar 32 mm² Rigid Al-Cable 2 x 95 ... 120 mm² Rigid Cu-Cable 16 ... 240 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 1 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V DC) 400 A (440 V DC) 400 A (600 V DC) 400 A
Ambient Air TemperatureOperation -40 ... 70 °C Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g
Object Classification CodeQ
ETIM 7EC002552 - Power contactor, DC switching
ETIM 8EC002552 - Power contactor, DC switching
ETIM 9EC002552 - Power contactor, DC switching
eClassV11.0 : 27371018
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
Manufacturer ID1SFL557025R7211

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.