- GAF460-10-11-69
The ABB GAF460-10-11-69 is an AC contactor with one normally open main contact, one normally open auxiliary contact, and one normally closed auxiliary contact. Its rated operational voltage for the main circuit is 1000 V, with a rated impulse withstand voltage of 8 kV and a rated insulation voltage of 1000 V according to UL/CSA. Conventional free-air thermal current is 700 A per IEC 60947-4-1 for open contactors at 40 °C. The coil operates at 48 to 130 V for 50 Hz, 60 Hz, and DC, with coil operating limits of 0.85 x Uc minimum to 1.1 x Uc maximum at temperatures up to 70 °C. Mechanical durability is 3 million cycles, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, weighing 10.6 kg.
- GAF460-10-11-70
The ABB GAF460-10-11-70 is a 3-pole AC contactor for DC-1 switching, with manufacturer ID 1SFL597025R7011. It has one main NO contact, one auxiliary NO contact, and one auxiliary NC contact. The main circuit is rated 1000 V, with conventional free-air thermal current 700 A according to IEC 60947-4-1 at 40 °C. Rated operational current DC-1 is 700 A at 40 °C, 600 A at 55 °C, and 480 A at 70 °C, with three poles in series. Rated control circuit voltage is 100 to 250 V at 50 Hz, 60 Hz, or DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg. Main terminals are bars; main terminals IP00, coil terminals IP20.
- GAF460-10-11-71
The ABB GAF460-10-11-71 is a 3-pole AC contactor with one normally open main contact, one normally open auxiliary contact, and one normally closed auxiliary contact. Its rated operational voltage for the main circuit is 1000 V, with a rated insulation voltage of 1000 V according to UL/CSA and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current DC-1 is 700 A at 1000 V with three poles in series at 40 °C, 600 A at 55 °C, and 480 A at 70 °C. The coil operates at 250 to 500 V for 50 Hz, 60 Hz, and DC. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg.
- GAF750-10-11-68
The ABB GAF750-10-11-68 is a 3-pole DC contactor with one normally open main contact and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V, with a rated impulse withstand voltage of 8 kV and a rated insulation voltage of 1000 V according to UL/CSA. Conventional free-air thermal current is 1050 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current DC-1 at 1000 V with three poles in series is 1050 A at 40 °C, 875 A at 55 °C, and 720 A at 70 °C. The DC control circuit voltage is 24 to 60 V. Mechanical durability is 3 million cycles, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 14 kg.
- GAF750-10-11-69
The ABB GAF750-10-11-69 is a 3-pole AC contactor with one normally open main contact and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V, with a rated insulation voltage of 1000 V according to UL/CSA and a rated impulse withstand voltage of 8 kV. Conventional free-air thermal current is 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current DC-1 is 1050 A at 1000 V with three poles in series at 40 °C, 875 A at 55 °C, and 720 A at 70 °C. The coil operates from 48 to 130 V at 50 Hz, 60 Hz, or DC. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high, weighing 14 kg.
- GAF750-10-11-70
The ABB GAF750-10-11-70 is a 3-pole AC contactor with one normally open main contact and one normally open plus one normally closed auxiliary contact. The main circuit is rated 1000 V, with a conventional free-air thermal current of 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current DC-1 is 1050 A at 1000 V with three poles in series at 40 °C, 875 A at 55 °C, and 720 A at 70 °C. Rated insulation voltage is 1000 V according to UL/CSA, and rated impulse withstand voltage is 8 kV. The coil accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Mechanical durability is 3 million operating cycles, with a maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 14 kg.
- GAF750-10-11-71
The ABB GAF750-10-11-71 is a 3-pole AC contactor with one normally open main contact and one NO plus one NC auxiliary contact. The main circuit is rated 1000 V, with conventional free-air thermal current of 1050 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current DC-1 is 1050 A at 1000 V with three poles in series at 40 °C, 875 A at 55 °C, and 720 A at 70 °C. Rated insulation voltage is 1000 V according to UL/CSA, and rated impulse withstand voltage is 8 kV. Mechanical durability is 3 million operations, with maximum mechanical switching frequency of 300 cycles per hour. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 14 kg.
- GAFX-1-G
ABB GAFX-1-G is an industrial catalog item. Key specifications include Application: Junction for Branch Conduits in Hazardous Locations, Product Type: Conduit Outlet Box with Cover, Number of Batteries: 0, and Color: Gray. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.