- AF305-30-00-12
The ABB AF305-30-00-12 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V and 50/60 Hz. Conventional free-air thermal current is 500 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, with rated operational power AC-3 of 160 kW at 415 V. The control circuit voltage range is 48 to 130 V for 50 Hz, 60 Hz, and DC operation. Coil consumption is 17 V·A holding at 50/60 Hz and 2.5 W holding at DC. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg. Main terminals are bars.
- AF305-30-00-13
The ABB AF305-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-00-14
The ABB AF305-30-00-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V, 440 V, and 380/400 V at 55 °C, and 290 A at 500 V and 690 V at 55 °C. Rated operational power AC-3 is 160 kW at 415 V, 440 V, and 380/400 V, and 250 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF305-30-00-31
The ABB AF305-30-00-31 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit voltage of 1000 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V, both at 60 °C. Rated operational power AC-3 is 160 kW at 415 V and 440 V, and 250 kW at 690 V. The contactor has a rated insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C), and 1000 V according to UL/CSA. Dimensions are 225 mm high, 140 mm wide, and 191 mm deep, with a net weight of 3.9 kg.
- AF305-30-00-32
The ABB AF305-30-00-32 is a three-pole AC/DC operated IEC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 440 V at 60 °C, and rated operational power AC-3 is 160 kW at 415 V and 440 V. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high, with a net weight of 3.9 kg. Manufacturer ID: 1SFL587002R3200.
- AF305-30-00-33
The ABB AF305-30-00-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 415 V and 55 °C, and AC-3 rated operational power is 160 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg. Manufacturer ID: 1SFL587002R3300.
- AF305-30-00-34
The ABB AF305-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 140 mm wide, 195.5 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 55 °C, and rated operational power AC-3 is 160 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour for AC-1 and AC-3.
- AF305-30-00-42
The ABB AF305-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V and a frequency of 50/60 Hz. The conventional free-air thermal current is 500 A according to IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 305 A at 415 V and 60 °C, and rated operational power AC-3 is 160 kW at 415 V. The contactor has a rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg.