- CM-PVS.41P
ABB CM-PVS.41P is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of module: voltage monitoring relay, Controlled parameter1: too low voltage, and Controlled parameter: overvoltage. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CM-PVS.41S
The ABB CM-PVS.41S is a three-phase monitoring relay, manufacturer ID 1SVR730794R3300. It monitors phase failure, phase sequence, and over- and undervoltage across a measuring range of 300 to 500 V AC (L-L), with a rated control supply voltage of 300 to 500 V AC (L-L) and rated frequency of 50/60 Hz. Timing includes a start-up delay of up to 200 ms and a tripping delay of 0 s or 0.1 to 30 s, selectable ON or OFF. Output is two changeover (SPDT) contacts via screw terminals, rated 4 A at 230 V AC-12 and 3 A at 230 V AC-15. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; weight is 0.139 kg. Housing protection is IP50, terminals IP20.
- CM-PVS.81P
ABB CM-PVS.81P is an industrial catalog item. Key specifications include Manufacturer: ABB, Type of module: voltage monitoring relay, Controlled parameter1: too low voltage, and Controlled parameter: overvoltage. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- CM-PVS.81S
ABB CM-PVS.81S intermediate relay for three-phase monitoring, with phase failure detection, phase sequence monitoring, and over- and undervoltage monitoring. Measuring and rated control supply voltage: (L-L) 200 ... 400 V AC; rated frequency 50/60 Hz. Time range: 200 ms start-up delay and 0 s or 0.1 ... 30 s tripping delay (ON or OFF). Output: 2 c/o (SPDT) contacts via screw terminals. Rated operational currents: AC-12 (230 V) 4 A, AC-15 (230 V) 3 A, DC-12 (24 V) 4 A, DC-13 (24 V) 2 A. Dimensions 22.5 x 85.6 x 103.7 mm; weight 0.136 kg. Housing IP50, terminals IP20. DIN rail mounting per IEC 60715.
- CM-SFS.21P
ABB CM-SFS.21P intermediate relay, order code 1SVR740760R0400, provides over- and undercurrent monitoring. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Start-up delay and tripping delay are each 0 s or 0.1 to 30 s, with the tripping delay selectable ON or OFF. Rated control supply voltage is 24 to 240 V AC/DC. Output is 2 x 1 c/o or 1 x 2 c/o contacts with selectable operating principle. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13. Minimum switching capacity is 24 V 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; weight 0.139 kg. Housing IP50, terminals IP20.
- CM-SFS.21S
ABB CM-SFS.21S intermediate relay, manufacturer ID 1SVR730760R0400, provides over- and undercurrent monitoring. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Time range is 0 s or 0.1 to 30 s start-up delay and 0 s or 0.1 to 30 s tripping delay, selectable ON or OFF. Rated control supply voltage is 24 to 240 V AC/DC. Output is 2 x 1 c/o or 1 x 2 c/o contacts with selectable operating principle. Screw terminals. Rated operational currents: AC-12 (230 V) 4 A, AC-15 (230 V) 3 A, DC-12 (24 V) 4 A, DC-13 (24 V) 2 A. Minimum switching capacity 24 V 10 mA. Dimensions 22.5 x 85.6 x 103.7 mm; net weight 0.15 kg. Housing IP50, terminals IP20; overvoltage category III, pollution degree 3.
- CM-SFS.22S
ABB CM-SFS.22S intermediate relay, manufacturer ID 1SVR730760R0500, for over- and undercurrent monitoring. Measuring ranges are 0.3 to 1.5 A, 1 to 5 A, and 3 to 15 A. Start-up and tripping delays are selectable as 0 s or 0.1 to 30 s, with ON or OFF operation. Rated control supply voltage is 24 to 240 V AC/DC. Output is 2 x 1 c/o or 1 x 2 c/o contacts with selectable operating principle. Screw terminals are used. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep; net weight is 0.158 kg. Housing protection is IP50 and terminals IP20. Overvoltage category III, pollution degree 3.
- CM-SRS.11P
ABB CM-SRS.11P intermediate relay, order code 1SVR740840R0200, monitors over- or undercurrent in single-phase systems. Measuring ranges are 3 to 30 mA, 10 to 100 mA, and 0.1 to 1 A. Rated control supply voltage is 24 to 240 V AC/DC. Output is one changeover (SPDT) contact with screwless terminals. Rated operational currents are 4 A at 230 V AC-12, 3 A at 230 V AC-15, 4 A at 24 V DC-12, and 2 A at 24 V DC-13; minimum switching capacity is 24 V, 10 mA. Dimensions are 22.5 mm wide, 85.6 mm high, and 103.7 mm deep, weighing 0.137 kg. Housing protection is IP50, terminals IP20, overvoltage category III, pollution degree 3.