- AF30-30-00K-13M
The ABB AF30-30-00K-13M is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V and 415 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-14
The ABB AF30-30-00K-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.37 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 32 A at 380/400 V and 415 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-11-11
ABB AF30-30-11-11 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-11-12
The ABB AF30-30-11-12 is a 3-pole AC contactor with 3 NO main contacts, 1 NO auxiliary contact, and 1 NC auxiliary contact. It is rated 15 kW at 400 V and 415 V AC-3, with AC-3 operational current of 32 A at 415 V and 60 °C. Rated operational voltage is 690 V for main and auxiliary circuits; rated frequency is 50/60 Hz. Coil voltage range is 48 to 130 V at 50 Hz, 60 Hz, and DC. It uses screw terminals and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or on 2 x M4 screws placed diagonally. Dimensions are 45 mm wide, 111.5 mm deep, 86 mm high; net weight 0.35 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-11-13
The ABB AF30-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF30-30-11-14
ABB AF30-30-11-14 AC contactor, manufacturer ID 1SBL277001R1411. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Dimensions are 45 mm wide, 111.5 mm deep, and 86 mm high; net weight is 0.39 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-22-11
The ABB AF30-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-1 rated operational current is 50 A at 40 °C and 42 A at 60 °C at 690 V. AC-3 rated operational power is 15 kW at 400 V and 18.5 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF30-30-22-12
The ABB AF30-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 32 A at 415 V and 60 °C, with rated operational power of 15 kW at 400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL277001R1222.