- AF30-30-11-13
The ABB AF30-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF30-30-11-14
ABB AF30-30-11-14 AC contactor, manufacturer ID 1SBL277001R1411. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Dimensions are 45 mm wide, 111.5 mm deep, and 86 mm high; net weight is 0.39 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-22-11
The ABB AF30-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-1 rated operational current is 50 A at 40 °C and 42 A at 60 °C at 690 V. AC-3 rated operational power is 15 kW at 400 V and 18.5 kW at 440 V, 500 V, and 690 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF30-30-22-12
The ABB AF30-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.36 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 32 A at 415 V and 60 °C, with rated operational power of 15 kW at 400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SBL277001R1222.
- AF30-30-22-13
ABB AF30-30-22-13 AC contactor, manufacturer ID 1SBL277001R1322. Three main contacts NO, zero NC; two auxiliary contacts NO and two NC. Rated operational voltage 690 V for main and auxiliary circuits; rated frequency 50/60 Hz. Rated control circuit voltage 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational current AC-3: 32 A at 415 V and 440 V, 28 A at 500 V, 21 A at 690 V, at 60 °C. Rated operational power AC-3: 15 kW at 400 V, 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Dimensions 45 x 119.5 x 86 mm; net weight 0.36 kg. Screw terminals, IP20.
- AF30-30-22-14
The ABB AF30-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 45 mm wide, 119.5 mm deep, and 86 mm high, and weighs 0.4 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 32 A at 415 V and 440 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF300-30-11-70
The ABB AF300-30-11-70 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 305 A at 380/400 V and 55 °C, and 300 A at 415 V and 55 °C. AC-3 rated operational power is 160 kW at 415 V and 250 kW at 690 V. Dimensions are 140 mm wide, 180.5 mm deep, and 227 mm high, with a net weight of 5.1 kg.
- AF300-30-11-72
The ABB AF300-30-11-72 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180.5 mm deep, and 227 mm high, and weighs 5.05 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 500 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-1 is 500 A at 690 V and 40 °C, 400 A at 55 °C, and 325 A at 70 °C. AC-3 ratings include 305 A at 380/400 V and 55 °C, and 280 A at 440 V, 500 V, and 690 V at 55 °C. Short-circuit protection uses gG type fuses rated 500 A.