- AF38-30-00K-12
The ABB AF38-30-00K-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings include 38 A at 380/400 V and 18.5 kW at 380/400 V, both at 60 °C. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Maximum electrical switching frequency is 1200 cycles per hour in AC-3.
- AF38-30-00K-13
ABB AC contactor AF38-30-00K-13, manufacturer ID 1SBL297005R1300. Three main contacts NO, no auxiliary contacts. Rated operational voltage 690 V main circuit; rated frequency 50/60 Hz control and main circuits. Rated control circuit voltage 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational current AC-3: 38 A at 415 V and 440 V, 33 A at 500 V, 24 A at 690 V, 40 A at 220/230/240 V, all at 60 °C. Rated operational power AC-3: 18.5 kW at 415 V, 22 kW at 440 V, 500 V, and 690 V, 11 kW at 220/230/240 V. Dimensions 45 mm wide, 86 mm deep, 92.3 mm high; weight 0.33 kg. Push-in spring terminals, IP20. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-30-00K-13M
ABB AF38-30-00K-13M is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, weighing 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 38 A at 380/400 V and 415 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 415 V, 22 kW at 440 V, 500 V, and 690 V, and 11 kW at 220/230/240 V. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1. Manufacturer ID 1SBL297005M1300.
- AF38-30-00K-14
The ABB AF38-30-00K-14 is a 3-pole AC contactor with push-in spring terminals and no auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with AC-3 ratings of 38 A at 380/400 V and 18.5 kW at 380/400 V, both at 60 °C. Control circuit voltage is 250 to 500 V at 50 Hz, 60 Hz, and DC. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, weighs 0.37 kg, and mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-30-11-11
ABB AF38-30-11-11 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 440 V, 33 A at 500 V, and 24 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38-30-11-12
The ABB AF38-30-11-12 is an AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.35 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 38 A at 415 V and 60 °C, with rated operational power of 18.5 kW at 400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF38-30-11-13
ABB AF38-30-11-13 AC contactor, manufacturer ID 1SBL297001R1311. It has three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Rated operational current AC-3 is 38 A at 415 V and 60 °C, 33 A at 500 V, and 24 A at 690 V. Rated operational power AC-3 is 18.5 kW at 400 V and 22 kW at 440 V. Dimensions are 45 mm width, 111.5 mm depth, 86 mm height, 0.35 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF38-30-11-14
ABB AF38-30-11-14 AC contactor, manufacturer ID 1SBL297001R1411, with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 45 mm wide, 111.5 mm deep, and 86 mm high, and weighs 0.39 kg. Rated operational voltage is 690 V for both main and auxiliary circuits, at 50/60 Hz. Conventional free-air thermal current is 50 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 38 A at 415 V and 24 A at 690 V, both at 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.