- AF146-30-22B-43
The ABB AF146-30-22B-43 is a 3-pole AC contactor with double clamp, identified by manufacturer ID 1SFL467002R4322. It has 3 main contacts NO and no main contacts NC, plus 2 auxiliary contacts NO and 2 auxiliary contacts NC. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 225 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 146 A at 415 V and 440 V, 130 A at 500 V, 93 A at 690 V, and 60 A at 1000 V, each at 60 °C. Rated operational power AC-3 is 75 kW at 415 V and 380/400 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high; net weight is 1.3 kg.
- AF146B-30-22-11
The ABB AF146B-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V. Rated operational power in AC-3 is 75 kW at 380/400 V and 415 V, 90 kW at 440 V, 500 V, and 690 V, and 45 kW at 220/230/240 V. Rated operational current AC-3 at 55 °C is 146 A at 380/400 V and 415 V, 130 A at 440 V and 500 V, 93 A at 690 V, and 60 A at 1000 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF146B-30-22-12
The ABB AF146B-30-22-12 is a 3-pole IEC AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 1000 V. AC-3 ratings include 146 A at 415 V and 55 °C, and 75 kW at 415 V and 380/400 V. AC-1 ratings include 225 A at 1000 V and 40 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF146B-30-22-13
ABB AF146B-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 1000 V, with AC-1 rated operational current of 225 A at 1000 V and 40 °C. AC-3 rated operational power is 75 kW at 415 V and 380/400 V, and 90 kW at 440 V, 500 V, and 690 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SFL467063R1322.
- AF146B-30-22-14
The ABB AF146B-30-22-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated 1000 V in the main circuit, with AC-3 ratings of 146 A at 415 V and 75 kW at 415 V, and AC-1 ratings up to 225 A at 40 °C. Control circuit voltage is 250 to 500 V at 50/60 Hz or DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight is 1.55 kg. Mechanical durability is 5 million operations. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF146B-30-22RT-11
The ABB AF146B-30-22RT-11 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V. Rated operational current AC-1 is 225 A at 1000 V and 40 °C, and 200 A at 1000 V and 55 °C. Rated operational power AC-3 is 75 kW at 380/400 V and 415 V, and 90 kW at 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.
- AF146B-30-22RT-12
The ABB AF146B-30-22RT-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated 1000 V. Rated operational current AC-3 is 146 A at 380/400 V and 415 V at 55 °C, and rated operational power AC-3 is 75 kW at 380/400 V and 415 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Manufacturer ID: 1SFL467062R1222.
- AF146B-30-22RT-13
The ABB AF146B-30-22RT-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 126 mm deep, and 150 mm high, and weighs 1.3 kg. The main circuit is rated for 1000 V operational voltage. AC-3 ratings include 146 A at 415 V and 55 °C, 130 A at 440 V and 55 °C, 93 A at 690 V and 55 °C, and 60 A at 1000 V and 55 °C, with corresponding AC-3 power ratings of 75 kW at 415 V and 90 kW at 440 V, 500 V, and 690 V. It is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1.