- AF30-30-00-12
The ABB AF30-30-00-12 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit voltage of 48 to 130 V at 50 Hz, 60 Hz, or DC. Rated operational current AC-3 is 32 A at 380/400 V and 415 V at 60 °C, and rated operational power AC-3 is 15 kW at 400 V. It complies with IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, and CSA C22.2 No. 60947-4-1. Dimensions are 45 mm wide, 86 mm deep, and 86 mm high, with a net weight of 0.31 kg. Screw terminals accept main circuit conductors from 1.5 to 10 mm². Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally.
- AF30-30-00-13
The ABB AF30-30-00-13 is a 3-pole AC contactor with screw terminals and no auxiliary contacts. It has a rated operational voltage of 690 V in the main circuit and a rated control circuit voltage of 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. Rated operational power AC-3 is 15 kW at 400 V and 18.5 kW at 440 V, 500 V, and 690 V. Conventional free-air thermal current is 50 A at 40 °C per IEC 60947-4-1. Dimensions are 45 mm wide, 86 mm deep, and 86 mm high, with a net weight of 0.31 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00-14
The ABB AF30-30-00-14 is a non-reversing 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 86 mm high, and weighs 0.35 kg. The main circuit is rated 690 V at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 50 A at 40 °C. AC-3 ratings include 32 A at 415 V and 60 °C, and 21 A at 690 V and 60 °C, with rated operational power of 15 kW at 400 V and 18.5 kW at 440 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-11
The ABB AF30-30-00K-11 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current is 50 A at AC-1 (690 V, 40 °C) and 32 A at AC-3 (380/400 V, 415 V, or 440 V, 60 °C). Rated operational power at AC-3 is 15 kW at 380/400 V or 415 V and 18.5 kW at 440 V, 500 V, or 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-12
ABB AF30-30-00K-12 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is identified by manufacturer ID 1SBL277005R1200. The control circuit accepts 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Rated operational voltage for the main circuit is 690 V, with rated frequency 50/60 Hz. Rated operational power AC-3 is 15 kW at 415 V and 380/400 V, 18.5 kW at 440, 500, and 690 V, and 9 kW at 220/230/240 V. Dimensions are 45 mm width, 86 mm depth, and 92.3 mm height, weighing 0.33 kg. Terminals are push-in spring type. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-13
The ABB AF30-30-00K-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 690 V and a control circuit voltage of 100 to 250 V at 50/60 Hz or DC. AC-3 rated operational power is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V, at 60 °C. Conventional free-air thermal current is 50 A at 40 °C. Dimensions are 45 mm wide, 86 mm deep, and 92.3 mm high, with a net weight of 0.33 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-13M
The ABB AF30-30-00K-13M is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.33 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 32 A at 380/400 V and 415 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, 18.5 kW at 440 V, 500 V, and 690 V, and 9 kW at 220/230/240 V. Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-16, UL 60947-4-1, CSA C22.2 No. 60947-4-1.
- AF30-30-00K-14
The ABB AF30-30-00K-14 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 86 mm deep, and 92.3 mm high, and weighs 0.37 kg. The main circuit is rated 690 V, with a control and main circuit frequency of 50/60 Hz. Conventional free-air thermal current is 50 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 32 A at 380/400 V and 415 V, 28 A at 500 V, and 21 A at 690 V, all at 60 °C. Rated operational power AC-3 is 15 kW at 380/400 V and 415 V, and 18.5 kW at 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1.