- AF38ZB-40-00-22
The ABB AF38ZB-40-00-22 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It is rated 55 A conventional free-air thermal current (Ith) at 40 °C and 55 A AC-1 at 690 V, 40 °C. AC-3 ratings include 22 A at 380/400 V, 60 °C, corresponding to 11 kW at 400 V. The control circuit operates at 48 to 130 V AC (50/60 Hz) or 48 to 130 V DC. Main circuit rated operational voltage is 690 V; rated insulation voltage is 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, weighing 0.41 kg. Screw terminals accept main circuit conductors from 1.5 to 16 mm². Standards include IEC/EN 60947-4-1 and UL 60947-4-1. Manufacturer ID: 1SBL296261R2200.
- AF38ZB-40-00-23
The ABB AF38ZB-40-00-23 is a 4-pole AC contactor with four NO main contacts and no auxiliary contacts, using screw terminals. It is rated 690 V in the main circuit and 600 V maximum operating voltage per UL/CSA, with a rated impulse withstand voltage of 6 kV. The control circuit accepts 100 to 250 V at 50/60 Hz and 100 to 250 V DC. Rated operational power is 11 kW at 400, 415, 440, and 500 V AC-3, and 9 kW at 690 V AC-3. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.41 kg. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715, or with two M4 screws placed diagonally.
- AF38ZB-40-00RT-21
ABB AF38ZB-40-00RT-21 is a four-pole AC contactor with four normally open main contacts and no auxiliary contacts. The control circuit accepts 24 to 60 V AC at 50 or 60 Hz and 20 to 60 V DC. Main circuit rated operational voltage is 690 V; rated operational power AC-3 is 11 kW at 400 V, 415 V, 440 V, and 500 V, and 9 kW at 690 V. Rated operational current AC-3 is 22 A at 380/400 V at 60 °C. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high, with a net weight of 0.39 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715 or on two M4 screws placed diagonally. Standards include IEC/EN 60947-4-1 and UL 60947-4-1.
- AF38ZB-40-00RT-22
ABB AF38ZB-40-00RT-22 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. It measures 45 mm wide, 101 mm deep, and 86 mm high, and weighs 0.39 kg. The main circuit is rated 690 V, with a rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA, and a rated impulse withstand voltage of 6 kV. Control circuit voltage is 48 to 130 V at 50 Hz, 48 to 130 V at 60 Hz, and 48 to 130 V DC. Conventional free-air thermal current is 55 A according to IEC 60947-4-1 for open contactors at 40 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1, IEC 60077-2, and EN 50155.
- AF38ZB-40-00RT-23
The ABB AF38ZB-40-00RT-23 is a 4-pole AC contactor with four normally open main contacts and no auxiliary contacts. Its control circuit accepts 100 to 250 V at 50 Hz, 100 to 250 V at 60 Hz, and 100 to 250 V DC. The main circuit is rated 690 V, 50/60 Hz, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V to IEC 60947-4-1 and 600 V to UL/CSA. Conventional free-air thermal current is 55 A at 40 degrees C. AC-3 ratings include 22 A at 380/400 V and 11 kW at 400, 415, 440, and 500 V. Dimensions are 45 mm wide, 101 mm deep, and 86 mm high; weight is 0.39 kg.
- AF40-22-00-11
The ABB AF40-22-00-11 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, and weighs 1.21 kg. The main circuit is rated 690 V at 50/60 Hz, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V according to IEC 60947-4-1 and 600 V according to UL/CSA. Conventional free-air thermal current is 105 A at 40 degrees C. AC-1 rated operational current is 70 A at 40 degrees C, 60 A at 60 degrees C, and 50 A at 70 degrees C, all at 690 V. AC-3 ratings include 40 A at 415 V and 25 A at 690 V, both at 60 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF40-22-00-12
The ABB AF40-22-00-12 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, weighing 1.21 kg. The main circuit is rated 690 V, 50/60 Hz, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V per IEC 60947-4-1 and 600 V per UL/CSA. Conventional free-air thermal current is 105 A at 40 °C. AC-1 ratings are 70 A at 40 °C, 60 A at 60 °C, and 50 A at 70 °C at 690 V. AC-3 ratings include 40 A at 380/400 V and 18.5 kW at 380/400 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF40-22-00-13
The ABB AF40-22-00-13 is a 4-pole AC contactor with two normally open and two normally closed main contacts, and no auxiliary contacts. It has a rated operational voltage of 690 V for the main circuit and operates at 50/60 Hz for both control and main circuits. Rated operational current AC-3 is 40 A at 380/400 V and 415 V, 35 A at 500 V, and 25 A at 690 V, all at 60 °C. Rated operational power AC-3 is 18.5 kW at 380/400 V and 22 kW at 415 V, 440 V, 500 V, and 690 V. The contactor measures 70 mm wide, 113.5 mm deep, and 125.5 mm high, and weighs 1.16 kg. It is declared to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.