- AF265-30-00-31
ABB AF265-30-00-31 AC contactor, manufacturer ID 1SFL547002R3100. Three-pole non-reversing contactor with 3 NO main contacts and no auxiliary contacts. Main circuit rated operational voltage 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 400 A per IEC 60947-4-1, open contactors, 40 °C. Rated operational current AC-1: 350 A at 1000 V, 40 °C; 300 A at 1000 V, 60 °C; 400 A at 690 V, 40 °C. Rated operational current AC-3: 265 A at 415 V, 60 °C; 250 A at 690 V, 60 °C. Rated operational power AC-3: 132 kW at 415 V; 200 kW at 690 V. Rated insulation voltage Ui 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Dimensions 140 mm width, 191 mm depth, 225 mm height; weight 3.9 kg.
- AF265-30-00-32
The ABB AF265-30-00-32 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V to IEC 60947-4-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 400 A to IEC 60947-4-1 at 40 °C. AC-3 rated operational current is 265 A at 415 V and 60 °C, with rated operational power of 132 kW at 415 V. The control circuit accepts 48 to 130 V at 50 Hz, 60 Hz, or DC. Mechanical durability is 5 million operating cycles. Dimensions are 140 mm wide, 191 mm deep, and 225 mm high; net weight 3.9 kg.
- AF265-30-00-33
The ABB AF265-30-00-33 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V and 60 Hz. Conventional free-air thermal current is 400 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, 250 A at 500 V and 55 °C, and 113 A at 1000 V and 55 °C. Rated operational power AC-3 is 132 kW at 415 V and 160 kW at 690 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high; net weight is 3.9 kg. Short-circuit protection uses gG type fuses rated 500 A.
- AF265-30-00-34
The ABB AF265-30-00-34 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit operational voltage of 1000 V at 50 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 55 °C. Rated operational power AC-3 includes 132 kW at 415 V and 380/400 V, 160 kW at 440 V, 500 V, and 1000 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 195.5 mm deep, and 225 mm high, with a net weight of 3.9 kg.
- AF265-30-00-42
The ABB AF265-30-00-42 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and rated insulation voltage of 1000 V per IEC 60947-4-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 400 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 265 A at 415 V and 132 kW at 415 V. The control circuit is rated 110 to 120 V at 50 Hz and 60 Hz. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high, with a net weight of 3.9 kg. Main terminals accept bars; main terminals are IP00 and coil terminals IP20 per IEC 60529.
- AF265-30-00-43
The ABB AF265-30-00-43 is a three-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated for a main circuit of 1000 V and 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 440 V, 250 A at 500 V and 690 V, and 113 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 132 kW at 415 V and 380/400 V, 160 kW at 440 V, 500 V, and 1000 V, and 200 kW at 690 V. Dimensions are 140 mm wide, 180 mm deep, and 225 mm high; net weight is 3.9 kg.
- AF265-30-11-11
The ABB AF265-30-11-11 is a three-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, with rated operational power AC-3 of 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.
- AF265-30-11-12
The ABB AF265-30-11-12 is a three-pole AC contactor with one normally open and one normally closed auxiliary contact. It measures 140 mm wide, 180 mm deep, and 225 mm high, and weighs 3.9 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 400 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 265 A at 415 V and 55 °C, and rated operational power AC-3 is 132 kW at 415 V. Short-circuit protection uses gG type fuses rated 500 A. Maximum electrical switching frequency is 300 cycles per hour in AC-1 and AC-3.