- AFS400-30-12-69
The ABB AFS400-30-12-69 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 350 A at 690 V at 55 °C. Rated operational power AC-3 is 220 kW at 415 V and 440 V, 250 kW at 500 V, and 315 kW at 690 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AFS400-30-12-70
The ABB AFS400-30-12-70 is a three-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 400 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 350 A at 690 V at 55 °C, and 155 A at 1000 V at 55 °C. Rated operational power AC-3 is 220 kW at 415 V and 440 V, 250 kW at 500 V, 315 kW at 690 V, and 200 kW at 380/400 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AFS400-30-12-71
The ABB AFS400-30-12-71 is a 3-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz, with a rated impulse withstand voltage of 8 kV and insulation voltage of 1000 V according to IEC 60947-4-1 and VDE 0110 (Gr. C). Conventional free-air thermal current is 600 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 400 A at 415 V and 55 °C. The control circuit voltage range is 250 to 500 V for 50 Hz, 60 Hz, and DC operation. Main circuit terminals are bars; dimensions are 186 mm wide, 216 mm deep, and 278 mm high, weighing 10.6 kg.
- AFS460-30-12-68
The ABB AFS460-30-12-68 is a three-pole AC contactor with three normally open main contacts and no normally closed main contacts. It provides one normally open and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 400 A at 690 V at 55 °C. Rated operational power AC-3 is 250 kW at 415 V and 440 V, and 315 kW at 500 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high; net weight is 10.6 kg.
- AFS460-30-12-69
The ABB AFS460-30-12-69 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It is rated for a main circuit voltage of 1000 V at 50/60 Hz. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 400 A at 690 V at 55 °C. Rated operational power AC-3 is 250 kW at 415 V and 440 V, and 315 kW at 500 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg.
- AFS460-30-12-70
The ABB AFS460-30-12-70 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It is rated for a main circuit voltage of 1000 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V and 55 °C, and rated operational power AC-3 is 250 kW at 415 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. The manufacturer ID is 1SFL597081R7012.
- AFS460-30-12-71
ABB AFS460-30-12-71 is a 3-pole AC contactor, manufacturer ID 1SFL597081R7112. It has 3 normally open main contacts, 1 normally open auxiliary contact, and 2 normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 400 A at 690 V, and 200 A at 1000 V. Rated operational power AC-3 is 250 kW at 415 V and 440 V, 315 kW at 500 V, 355 kW at 690 V, and 280 kW at 1000 V. Dimensions are 186 mm wide, 216 mm deep, 278 mm high; net weight 10.6 kg.
- AFS52-30-22-11
ABB AFS52-30-22-11 is a 3-pole AC contactor with 3 N.O. main contacts and 2 N.O. plus 2 N.C. auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 53 A at 415 V and 440 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 55 mm wide, 144 mm deep, and 125.5 mm high, with a net weight of 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.