- AFS460-30-12-70
The ABB AFS460-30-12-70 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It is rated for a main circuit voltage of 1000 V and a frequency of 50/60 Hz. Conventional free-air thermal current is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V and 55 °C, and rated operational power AC-3 is 250 kW at 415 V. Dimensions are 186 mm wide, 216 mm deep, and 278 mm high, with a net weight of 10.6 kg. The manufacturer ID is 1SFL597081R7012.
- AFS460-30-12-71
ABB AFS460-30-12-71 is a 3-pole AC contactor, manufacturer ID 1SFL597081R7112. It has 3 normally open main contacts, 1 normally open auxiliary contact, and 2 normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current Ith is 700 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 460 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 400 A at 690 V, and 200 A at 1000 V. Rated operational power AC-3 is 250 kW at 415 V and 440 V, 315 kW at 500 V, 355 kW at 690 V, and 280 kW at 1000 V. Dimensions are 186 mm wide, 216 mm deep, 278 mm high; net weight 10.6 kg.
- AFS52-30-22-11
ABB AFS52-30-22-11 is a 3-pole AC contactor with 3 N.O. main contacts and 2 N.O. plus 2 N.C. auxiliary contacts. It is rated 690 V for both main and auxiliary circuits at 50/60 Hz. Rated operational current AC-3 is 53 A at 415 V and 440 V, 45 A at 500 V, and 35 A at 690 V, all at 60 °C. Rated operational power AC-3 is 22 kW at 400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Dimensions are 55 mm wide, 144 mm deep, and 125.5 mm high, with a net weight of 1.02 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AFS52-30-22-13
ABB AFS52-30-22-13 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 55 mm wide, 144 mm deep, and 125.5 mm high, and weighs 1 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Per IEC 60947-4-1, AC-1 rated operational current is 100 A at 690 V and 40 °C, 80 A at 60 °C, and 70 A at 70 °C. AC-3 rated operational power is 22 kW at 400 V and 30 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AFS580-30-12-68
The ABB AFS580-30-12-68 is a three-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. It measures 210 mm wide, 242 mm deep, and 283 mm high, and weighs 10 kg. The main circuit is rated for 1000 V and 50/60 Hz. Conventional free-air thermal current is 800 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 580 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, 500 A at 690 V, and 250 A at 1000 V. Rated operational power AC-3 is 355 kW at 415 V, 440 V, and 1000 V, 400 kW at 500 V, 500 kW at 690 V, and 315 kW at 380/400 V. Short-circuit protection uses gG type fuses rated 1000 A.
- AFS580-30-12-69
ABB AFS580-30-12-69 is a 3-pole AC contactor with three normally open main contacts, one normally open auxiliary contact, and two normally closed auxiliary contacts. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 800 A according to IEC 60947-4-1 for open contactors at 40 °C. AC-3 rated operational current is 580 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 500 A at 690 V at 55 °C. AC-3 rated operational power is 355 kW at 415 V and 440 V, 400 kW at 500 V, and 500 kW at 690 V. The control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 210 mm wide, 242 mm deep, and 283 mm high; net weight is 10 kg.
- AFS580-30-12-71
The ABB AFS580-30-12-71 is a 3-pole AC contactor with three normally open main contacts and pre-mounted auxiliary contacts (1 NO, 2 NC). It measures 210 mm wide, 242 mm deep, and 283 mm high, weighing 10 kg. The main circuit is rated 1000 V at 50/60 Hz. Conventional free-air thermal current is 800 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 580 A at 415 V, 440 V, 500 V, and 380/400 V at 55 °C, and 250 A at 1000 V at 55 °C. Rated operational power AC-3 is 355 kW at 415 V and 440 V, 400 kW at 500 V, and 500 kW at 690 V. Short-circuit protection uses gG type fuses rated 1000 A.
- AFS65-30-22-11
The ABB AFS65-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 55 mm wide, 144 mm deep, and 125.5 mm high, and weighs 1.02 kg. Main and auxiliary circuits are rated 690 V at 50/60 Hz. Conventional free-air thermal current is 105 A per IEC 60947-4-1 at 40 °C. Rated operational current AC-3 is 65 A at 415 V and 440 V, 55 A at 500 V, and 39 A at 690 V, all at 60 °C. Rated operational power AC-3 is 30 kW at 400 V and 37 kW at 415 V, 440 V, 500 V, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.