- AF116-30-22-33
The ABB AF116-30-22-33 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 50 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, and 380/400 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-22-34
The ABB AF116-30-22-34 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 90 mm wide, 142.5 mm deep, and 150 mm high, and weighs 1.55 kg. The main circuit is rated 690 V at 60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, and 380/400 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 380/400 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V.
- AF116-30-22-42
The ABB AF116-30-22-42 is a 3-pole AC contactor with three normally open main contacts and two NO plus two NC auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz, with AC-3 ratings of 116 A at 380/400 V and 55 kW at 400 V, both at 60 °C. Conventional free-air thermal current is 160 A per IEC 60947-4-1 at 40 °C. The coil is rated 110 to 120 V at 50 Hz and 60 Hz. Mechanical durability is 5 million operations. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg. Main terminals accept rigid copper cable from 10 to 95 mm²; auxiliary terminals accept 0.75 to 2.5 mm² flexible conductors.
- AF116-30-22-43
The ABB AF116-30-22-43 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 60 °C, 110 A at 500 V and 60 °C, and 65 A at 690 V and 60 °C. Rated operational power AC-3 is 55 kW at 400 V and 75 kW at 440 V. Dimensions are 110 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.55 kg.
- AF116-30-22B-11
ABB AF116-30-22B-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 380/400 V, 415 V, 440 V, and 220/230/240 V, 110 A at 500 V, and 65 A at 690 V, all at 55 °C. Rated operational power AC-3 is 55 kW at 380/400 V and 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high; net weight 1.3 kg. Manufacturer ID 1SFL427002R1122.
- AF116-30-22B-12
The ABB AF116-30-22B-12 is a 3-pole AC contactor with 3 normally open main contacts and 2 NO plus 2 NC auxiliary contacts. It is rated 690 V in the main circuit at 50/60 Hz, with a conventional free-air thermal current of 160 A according to IEC 60947-4-1 at 40 °C. AC-3 ratings include 116 A at 415 V and 55 kW at 415 V. The control circuit voltage is 48 to 130 V at 50 Hz, 60 Hz, and DC. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, weighing 1.3 kg. Terminal type for the main circuit is bars.
- AF116-30-22B-13
The ABB AF116-30-22B-13 is a three-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V and 55 °C, 110 A at 500 V and 55 °C, and 65 A at 690 V and 55 °C. Rated operational power AC-3 is 55 kW at 415 V and 75 kW at 500 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.
- AF116-30-22B-14
The ABB AF116-30-22B-14 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It is rated for a main circuit operational voltage of 690 V at 50/60 Hz. Conventional free-air thermal current is 160 A according to IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 116 A at 415 V, 440 V, 380/400 V, and 220/230/240 V at 55 °C, 110 A at 500 V, and 65 A at 690 V. Rated operational power AC-3 is 55 kW at 415 V, 75 kW at 440 V and 500 V, 55 kW at 690 V, and 30 kW at 220/230/240 V. Dimensions are 90 mm wide, 126 mm deep, and 150 mm high, with a net weight of 1.3 kg.