- AF96-30-11-11
The ABB AF96-30-11-11 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.26 kg. The main circuit is rated for 1000 V, the auxiliary circuit for 690 V, at 50/60 Hz. Per IEC 60947-4-1, conventional free-air thermal current is 130 A at 40 °C. AC-3 ratings include 105 A at 380/400 V and 60 °C, 96 A at 415 V and 60 °C, and 57 A at 690 V and 60 °C. Applicable standards are IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF96-30-11-12
The ABB AF96-30-11-12 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.26 kg. The main circuit is rated 1000 V and the auxiliary circuit 690 V, at 50/60 Hz. Rated operational current AC-3 is 105 A at 380/400 V and 220/230/240 V, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V, all at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF96-30-11-13
The ABB AF96-30-11-13 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.21 kg. The control circuit accepts 100 to 250 V at 50 Hz, 60 Hz, or DC. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit. Conventional free-air thermal current is 130 A at 40 °C to IEC 60947-4-1. AC-3 ratings include 105 A at 380/400 V and 57 A at 690 V, both at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF96-30-11-14
The ABB AF96-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one NO plus one NC auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.21 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Conventional free-air thermal current is 130 A per IEC 60947-4-1 at 40 °C. AC-3 ratings include 105 A at 380/400 V and 57 A at 690 V, both at 60 °C. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF96-30-22-11
The ABB AF96-30-22-11 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.27 kg. The main circuit is rated 1000 V and the auxiliary circuit 690 V, at 50/60 Hz. Rated operational current AC-3 is 105 A at 380/400 V and 220/230/240 V, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 45 kW at 380/400 V and 55 kW at 415, 440, 500, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF96-30-22-12
The ABB AF96-30-22-12 is a 3-pole AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.27 kg. Main circuit rated operational voltage is 1000 V; auxiliary circuit rated operational voltage is 690 V. Rated frequency is 50/60 Hz for main, control, and auxiliary circuits. Rated operational current AC-3 is 105 A at 380/400 V and 220/230/240 V, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF96-30-22-13
The ABB AF96-30-22-13 is an AC contactor with three normally open main contacts and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, and weighs 1.22 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 105 A at 380/400 V and 220/230/240 V, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415, 440, 500, and 690 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF96-30-22-14
The ABB AF96-30-22-14 is a 3-pole AC contactor with screw terminals, three normally open main contacts, and two normally open plus two normally closed auxiliary contacts. It measures 70 mm wide, 149 mm deep, and 125.5 mm high, weighing 1.22 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 105 A at 380/400 V and 60 °C, and rated operational power AC-3 is 45 kW at 380/400 V. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22. Manufacturer ID: 1SBL407001R1422.