- AF96B-30-00-12
ABB AF96B-30-00-12 is an AC contactor for three-phase motor and power circuit control, identified by manufacturer ID 1SBL407061R1200. It has three normally open main contacts and no auxiliary contacts. Dimensions are 70 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.22 kg. The main circuit is rated 1000 V, with a control circuit frequency of 50/60 Hz. Rated operational current AC-3 is 105 A at 380/400 V and 220/230/240 V at 60 °C, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AF96B-30-00-13
The ABB AF96B-30-00-13 is a 3-pole AC contactor with three normally open main contacts and no auxiliary contacts. It is rated 1000 V in the main circuit and operates at 50/60 Hz on both control and main circuits. Per IEC 60947-4-1, conventional free-air thermal current is 130 A at 40 °C. AC-1 rating is 130 A at 690 V and 40 °C. AC-3 ratings include 105 A at 380/400 V and 60 °C, and 30 A at 1000 V and 60 °C. AC-3 power ratings include 45 kW at 380/400 V. Dimensions are 70 mm wide, 116 mm deep, and 125.5 mm high; net weight is 1.17 kg. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF96B-30-00-14
ABB AF96B-30-00-14 AC contactor, manufacturer ID 1SBL407061R1400. Three main contacts, normally open, no auxiliary contacts. Main circuit rated operational voltage 1000 V; control and main circuit rated frequency 50/60 Hz. Conventional free-air thermal current per IEC 60947-4-1, open contactors at 40 °C, is 130 A. Rated operational current AC-3 at 60 °C: 105 A at 380/400 V and 220/230/240 V, 96 A at 415/440 V, 80 A at 500 V, 57 A at 690 V, 30 A at 1000 V. Rated operational power AC-3 at 60 °C: 55 kW at 415/440/500/690 V, 45 kW at 380/400 V. Dimensions 70 mm wide, 116 mm deep, 125.5 mm high; net weight 1.17 kg. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22.
- AF96B-30-11-12
The ABB AF96B-30-11-12 is an AC contactor with three normally open main contacts, one normally open auxiliary contact, and one normally closed auxiliary contact. It has a rated control circuit voltage of 48 to 130 V at 50 Hz, 60 Hz, and DC operation. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit. Rated operational current AC-3 is 105 A at 380/400 V and 60 °C, and 96 A at 415 V and 60 °C. Rated operational power AC-3 is 55 kW at 415 V. Dimensions are 82 mm wide, 116 mm deep, and 125.5 mm high, with a net weight of 1.26 kg. It mounts on TH35-15 DIN rail per IEC 60715 or with 2 x M4 or 2 x M6 screws. Standards include IEC/EN 60947-1 and IEC/EN 60947-4-1.
- AF96B-30-11-14
ABB AF96B-30-11-14 is a 3-pole AC contactor with three normally open main contacts and one normally open plus one normally closed auxiliary contact. It measures 82 mm wide, 116 mm deep, and 125.5 mm high, and weighs 1.21 kg. Rated operational voltage is 1000 V for the main circuit and 690 V for the auxiliary circuit, at 50/60 Hz. Rated operational current AC-3 is 96 A at 415 V and 440 V, 80 A at 500 V, 57 A at 690 V, and 30 A at 1000 V, all at 60 °C. Rated operational power AC-3 is 55 kW at 415 V, 440 V, 500 V, and 690 V. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, and CSA C22.2 No. 60947-4-1:22.
- AFBPH-P
ABB AFBPH-P is an industrial catalog item. Key specifications include Brand / Label: Homac, Effective Date: 20110928, Material: Aluminum, and Product Type: Flat Bus Plug - 4 inch Drive Fit. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- AFC09-22-00-34
ABB AFC09-22-00-34 AC contactor, manufacturer ID 1SBL131501R3400. It has 2 main contacts NO and 2 main contacts NC, with no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Conventional free-air thermal current is 35 A per IEC 60947-4-1 for open contactors at 40 °C. Rated operational current AC-3 is 9 A at 415 V, 440 V, 380/400 V, and 220/230/240 V, and 7 A at 690 V, all at 60 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.
- AFC09-22-00-51
ABB AC contactor AFC09-22-00-51, manufacturer ID 1SBL131501R5100. It has two normally open and two normally closed main contacts, with no auxiliary contacts. Dimensions are 45 mm wide, 77 mm deep, and 86 mm high; net weight 0.298 kg. The main circuit is rated 690 V at 50/60 Hz. Rated operational current AC-3 is 9 A at 415 V and 440 V, 9.5 A at 500 V, 7 A at 690 V, and 9 A at 380/400 V and 220/230/240 V, all at 60 °C. Rated operational power AC-3 is 4 kW at 415 V and 440 V, 5.5 kW at 500 V and 690 V, 4 kW at 380/400 V, and 2.2 kW at 220/230/240 V. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1.