- OT1250E30
The ABB OT1250E30 is a 3-pole, front-operated switch-disconnector for base mounting, with lug terminals and line terminals configurable as top in/bottom out or bottom in/top out. It is rated 1250 A at 380 to 415 V, 500 V, and 690 V for AC-21A, AC-22A, and AC-23A, with rated operational power AC-23A of 710 kW at 400 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V according to IEC/EN 60664-1, rated impulse withstand voltage is 12 kV, and rated short-time withstand current is 50 kA for 1 s. It conforms to IEC 60947-3. Dimensions are 334.5 mm wide, 306 mm high, and 145.5 mm deep; net weight is 14.7 kg. Front protection is IP00. Handle and shaft are not included.
- OT1250E30W4
ABB OT1250E30W4 is a 3-pole, front-operated isolating switch intended for base mounting. It is rated 1250 A conventional free-air thermal current at 40 °C and 1250 A conventional thermal current fully enclosed. Power loss is 29 W per pole at rated operating conditions. The switch has a phase distance of 140 mm, pollution degree 3, and front degree of protection IP00. Line terminals can be connected top in - bottom out or bottom in - top out. Mechanical durability is 6000 operations. Dimensions are 454.5 mm wide, 306 mm high, and 145.5 mm deep; net weight is 16.9 kg. Handle and shaft are not included. Manufacturer ID: 1SCA022871R7650.
- OT1250E30W4P
ABB OT1250E30W4P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 454.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1250EAUC3AZ
ABB OT1250EAUC3AZ is a three-pole isolating switch in a steel sheet enclosure, rated 1000 V and 1250 A. It is an enclosed switch disconnector with IP65 protection to IEC 60529 and IK09 impact resistance. Rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Short-time withstand current is 50 kA for 1 s. It has 2 NO and 1 NC auxiliary contacts, no neutral terminal, and a red/yellow pistol handle. Standards: IEC 60947-1, -3.
- OT1250EAUC3TZ
ABB OT1250EAUC3TZ isolating switch, manufacturer ID 1SCA103274R1001, in a steel sheet enclosure rated IP65 acc. to IEC 60529 and IK09 for impact. It is a 3-pole switch with no neutral terminal, a black pistol handle, and cable entry at bottom/bottom. Conventional thermal current (Ithe) is 1250 A fully enclosed; rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V acc. to IEC/EN 60664-1. Standards: IEC 60947-1, -3.
- OT1250EAUR3AZ
ABB OT1250EAUR3AZ is a three-pole enclosed isolating switch with a pistol handle in red/yellow and a steel sheet enclosure. It is rated 1250 A conventional thermal current (fully enclosed) and 1000 V rated insulation voltage acc. to IEC/EN 60664-1, with a rated operational voltage of 1000 V for the main circuit. Rated operational current AC-22A and AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Short-circuit making capacity is 110 kA at 690 V AC; short-time withstand current is 50 kA for 1 s. Degree of protection is IP65 acc. to IEC 60529, impact resistance IK09, pollution degree 3. Standards: IEC 60947-1, -3.
- OT1250EAUR3TZ
ABB isolating switch OT1250EAUR3TZ, 3-pole, in a steel sheet enclosure with IP65 protection to IEC 60529 and IK09 impact resistance. Conventional thermal current (Ithe) is 1250 A fully enclosed. Rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V to IEC/EN 60664-1. Rated short-time withstand current (Icw) is 50 kA for 1 s; rated short-circuit making capacity (Icm) is 110 kA at 690 V AC. Standards: IEC 60947-1, -3.
- OT1250ELAA3AZ
ABB isolating switch OT1250ELAA3AZ, manufacturer ID 1SCA102771R1001. Three-pole, front-operated, non-fusible design with a pistol handle in red/yellow. Rated insulation voltage is 1000 V per IEC/EN 60664-1; rated operational voltage of the main circuit is 1000 V. Conventional thermal current (Ithe) is 1250 A fully enclosed. Rated operational current AC-22A and AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated short-circuit making capacity is 110 kA at 690 V AC; rated short-time withstand current is 50 kA for 1 s. Standards: IEC 60947-1, -3. Enclosure is steel sheet, IP65 per IEC 60529, 800 mm wide, 1200 mm high, 330 mm deep, 59 kg.