- OT1250E30W4P
ABB OT1250E30W4P is listed in the Isolating switch category. Key specifications include Degree of Protection: Front IP00, Environmental Information: 1SCC301233D0201, Pollution Degree: 3, and Product Net Width: 454.5 mm. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- OT1250EAUC3AZ
ABB OT1250EAUC3AZ is a three-pole isolating switch in a steel sheet enclosure, rated 1000 V and 1250 A. It is an enclosed switch disconnector with IP65 protection to IEC 60529 and IK09 impact resistance. Rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Short-time withstand current is 50 kA for 1 s. It has 2 NO and 1 NC auxiliary contacts, no neutral terminal, and a red/yellow pistol handle. Standards: IEC 60947-1, -3.
- OT1250EAUC3TZ
ABB OT1250EAUC3TZ isolating switch, manufacturer ID 1SCA103274R1001, in a steel sheet enclosure rated IP65 acc. to IEC 60529 and IK09 for impact. It is a 3-pole switch with no neutral terminal, a black pistol handle, and cable entry at bottom/bottom. Conventional thermal current (Ithe) is 1250 A fully enclosed; rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V acc. to IEC/EN 60664-1. Standards: IEC 60947-1, -3.
- OT1250EAUR3AZ
ABB OT1250EAUR3AZ is a three-pole enclosed isolating switch with a pistol handle in red/yellow and a steel sheet enclosure. It is rated 1250 A conventional thermal current (fully enclosed) and 1000 V rated insulation voltage acc. to IEC/EN 60664-1, with a rated operational voltage of 1000 V for the main circuit. Rated operational current AC-22A and AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Short-circuit making capacity is 110 kA at 690 V AC; short-time withstand current is 50 kA for 1 s. Degree of protection is IP65 acc. to IEC 60529, impact resistance IK09, pollution degree 3. Standards: IEC 60947-1, -3.
- OT1250EAUR3TZ
ABB isolating switch OT1250EAUR3TZ, 3-pole, in a steel sheet enclosure with IP65 protection to IEC 60529 and IK09 impact resistance. Conventional thermal current (Ithe) is 1250 A fully enclosed. Rated operational current is 1250 A at 380 to 415 V, 500 V, and 690 V for AC-22A and AC-23A; rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated insulation voltage is 1000 V to IEC/EN 60664-1. Rated short-time withstand current (Icw) is 50 kA for 1 s; rated short-circuit making capacity (Icm) is 110 kA at 690 V AC. Standards: IEC 60947-1, -3.
- OT1250ELAA3AZ
ABB isolating switch OT1250ELAA3AZ, manufacturer ID 1SCA102771R1001. Three-pole, front-operated, non-fusible design with a pistol handle in red/yellow. Rated insulation voltage is 1000 V per IEC/EN 60664-1; rated operational voltage of the main circuit is 1000 V. Conventional thermal current (Ithe) is 1250 A fully enclosed. Rated operational current AC-22A and AC-23A is 1250 A at 380 to 415 V, 500 V, and 690 V. Rated operational power AC-23A is 710 kW at 380 to 415 V, 900 kW at 500 V, and 1200 kW at 690 V. Rated short-circuit making capacity is 110 kA at 690 V AC; rated short-time withstand current is 50 kA for 1 s. Standards: IEC 60947-1, -3. Enclosure is steel sheet, IP65 per IEC 60529, 800 mm wide, 1200 mm high, 330 mm deep, 59 kg.
- OT1250ELAA3TZ
ABB isolating switch OT1250ELAA3TZ, manufacturer ID 1SCA102766R1001. Three-pole, non-fusible open configuration with pistol handle, black handle color. Conventional thermal current (Ithe) 1250 A fully enclosed. Rated operational current AC-22A and AC-23A: 1250 A at 380–415 V, 500 V, and 690 V. Rated operational power AC-23A: 710 kW at 380–415 V, 900 kW at 500 V, 1200 kW at 690 V. Rated insulation voltage (Ui) 1000 V acc. to IEC/EN 60664-1. Degree of protection IP65 acc. to IEC 60529. Steel sheet enclosure, 800 mm wide, 1200 mm high, 330 mm deep, 59 kg. Cable entry up/down. Mounted auxiliary contacts 2 NO, 1 NC; maximum 2 NO, 2 NC.
- OT1250ELCC3AZ
The ABB OT1250ELCC3AZ is an enclosed isolating switch with a conventional thermal current (Ithe) of 1250 A when fully enclosed. The steel sheet enclosure measures 800 mm wide, 1200 mm high, and 330 mm deep, and weighs 62 kg. It provides IP65 protection according to IEC 60529 and an impact resistance rating of IK09 for the housing, with pollution degree 3. Cable entry is possible from the top or bottom, with 6xC-flange outlets per side and knock-outs of 3x10 mm, 12.5 mm, 2x20.5 mm, 2x25.5 mm, and 2x32.5 mm. The main circuit uses screw clamp connections with 12 mm hole diameter; the PE terminal accepts 10 pc, 25 to 120 mm². A red/yellow pistol handle is fitted. Mounted auxiliary contacts are 2 NO and 1 NC, with a maximum of 2 NO and 2 NC. No neutral terminal is included.