- BC7-40-00-F-2.4-51
ABB BC7-40-00-F-2.4-51 interface mini contactor with four poles and four normally open main contacts, no normally open or normally closed auxiliary contacts. Rated operational voltage is 690 V AC for the main circuit and 220 V DC; rated control circuit voltage is 17 to 32 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 40 °C and 55 °C at 690 V. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; weight 0.17 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- BC7-40-00-P-01
ABB BC7-40-00-P-01 mini contactor, 4-pole, with 4 NO main contacts and no NC main contacts. Main circuit rated 690 V AC and 220 V DC, rated impulse withstand voltage 6 kV, rated insulation voltage 690 V. Coil rated control circuit voltage 24 V DC, operating limits 0.85 to 1.1 x Uc at up to 55 °C per IEC 60947-4-1. Rated operational current AC-1: 12 A at 220/240 V and 380/440 V, 6 A at 690 V. Rated operational power AC-3: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V. Dimensions 47.5 x 45.2 x 47.7 mm, 0.17 kg. DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles.
- BC7-40-00-P2.4-51
ABB BC7-40-00-P2.4-51 interface mini contactor with four poles and four normally open main contacts, no normally closed main or auxiliary contacts. Rated operational voltage is 690 V AC and 220 V DC for the main circuit, with rated impulse withstand voltage 6 kV and rated insulation voltage 690 V. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V. Control circuit voltage is 17 to 32 V DC. Dimensions are 47.5 mm wide, 45.2 mm high, and 47.7 mm deep; net weight 0.17 kg. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- BC7-G
ABB BC7-G is an industrial catalog item. Key specifications include Application: Act As Pull Outlets for Conductors that are Stiff, Due to Large Size or Type of, Product Type: Mogul Conduit Outlet Bodies & Covers, Product Net Height: 3.63 in, and Product Net Depth / Length: 18.38 in. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- BC7-TB
ABB BC7-TB is an industrial catalog item. Key specifications include Application: Mogul Bodies are Installed In Conduit Systems to Act As Pull Outlets for Conduct, Product Type: Mogul Conduit Body & Cover, Number of Batteries: 0, and Material: Gray Iron. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- BC71
ABB BC71 is an industrial catalog item. Key specifications include Brand / Label: Sta-Kon, Color: Metallic, Effective Date: 19760419, and Material: Copper. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- BC72
ABB BC72 is an industrial catalog item. Key specifications include RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019, Brand / Label: Sta-Kon, Color: Metallic, and Effective Date: 19760419. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- BC72NP
ABB BC72NP is an industrial catalog item. Key specifications include Brand / Label: Sta-Kon, Effective Date: 20070731, Material: Copper, and Product Type: Non-Insulated Heavy-Duty Ring Terminal. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.