Industrial Automation Parts. Prompt replies from real people.

ABB BC7-40-00-P2.4-51 AC contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/26/2026

Q1Can you supply the ABB BC7-40-00-P2.4-51?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB BC7-40-00-P2.4-51 cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
BC7-40-00-P2.4-51
Material Number
GJL1313209R5001
Manufacturer
ABB
Product ID
69413

Get a Free Quote

Request pricing and availability for BC7-40-00-P2.4-51.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.17 kg
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW
See all specifications

Product Highlights

  1. Compact dimensions: 47.5 mm net width, 45.2 mm net height, 47.7 mm net depth and 0.17 kg net weight
  2. Contact configuration: 4 poles with 4 main contacts NO and no main or auxiliary NC contacts
  3. Main circuit ratings: 690 V AC and 220 V DC operational voltage, 6 kV impulse withstand voltage, 690 V UL/CSA and 600 V insulation voltage, 50/60 Hz and DC frequency
  4. AC-1 current: 12 A at 220/240 V and 380/440 V, 6 A at 690 V, both at 40 °C and 55 °C
  5. AC-3 motor power: 3 kW at 230 V, 5.5 kW at 400 V and 500 V, 3 kW at 690 V three-phase
  6. Short-time withstand current: 96 A at 40 °C in free air from a cold state for 10 s
  7. Control circuit: 17 to 32 V DC rated control voltage with DC control circuit frequency
  8. Durability and switching frequency: 10,000,000 mechanical cycles and up to 600 cycles per hour for AC-3, DC-1 and DC-3
  9. Terminal protection: IP20 for both control and main circuit terminals
  10. Mounting: TH35-15 and TH35-7.5 DIN rail according to IEC 60715
  11. Ambient conditions: operation -20 to +55 °C, storage -40 to +80 °C, maximum altitude 2000 m
  12. Shock and vibration resistance: 15g for 11 ms pulses according to IEC 60068-2-27 and 5g at 5 to 150 Hz
  13. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 and IEC 60335-2-40 A2L
  14. UL/CSA motor ratings: 13.8 A at 115 V single-phase, 7.8 A at 200 V three-phase, 9.6 A at 220/240 V three-phase, 10 A at 230 V single-phase, 7.6 A at 440/480 V three-phase and 6.1 A at 550/600 V three-phase
  15. UL/CSA horsepower ratings: 0.75 Hp at 115 V single-phase, 2 Hp at 200 V three-phase, 3 Hp at 220/240 V three-phase, 1.5 Hp at 230 V single-phase and 5 Hp at 440/480 V and 550/600 V three-phase
  16. UL/CSA general use rating: 12 A at 600 V AC
  17. Power loss: 1.4 W per pole at rated AC-1 operating conditions
  18. Connection: soldering pins
BC7-40-00-P2.4-51

Product Information

Technical Specifications

Specifications for BC7-40-00-P2.4-51

ParameterValue
Product Net Width47.5 mm
Product Net Height45.2 mm
Product Net Depth / Length47.7 mm
Product Net Weight0.17 kg
Number of Poles4
Mini Contactor TypeInterface Mini Contactor
Rated Operational VoltageMain Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)Control Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V acc. to UL/CSA 600 V
Number of Main Contacts NC0
Number of Main Contacts NO4
Rated Operational Current AC-1 (Ie)(220240 V) 40 °C 12 A (220240 V) 55 °C 12 A (380440 V) 40 °C 12 A (380440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)(230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
Number of Auxiliary Contacts NC0
Number of Auxiliary Contacts NO0
Conventional Free-air Thermal Current (Ith)Main Circuit 12 A
Rated Control Circuit Voltage (Uc)17 ... 32 V DC
Coil Operating Limits(acc. to IEC 60947-4-1) for DC supply Uc Min. ... Uc Max. (at θ ≤ 55 °C)
ParameterValue
Degree of ProtectionControl Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability10000000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Lossat Rated Operating Conditions AC-1 per Pole 1.4 W
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
RemarksNo CA6 or CAF6 mountable
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Full Load Amps Motor Use(115 V AC) Single Phase 13.8 A (200 V AC) Three Phase 7.8 A (220 ... 240 V AC) Three Phase 9.6 A (230 V AC) Single Phase 10 A (440 ... 480 V AC) Three Phase 7.6 A (550 ... 600 V AC) Three Phase 6.1 A
Horsepower Rating UL/CSA(115 V AC) Single Phase 0.75 Hp (200 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 3 Hp (230 V AC) Single Phase 1.5 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 5 Hp
General Use Rating UL/CSA(600 V AC) 12 A
Ambient Air TemperatureOperation -20 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Resistance to Vibrations5g 5 ... 150 Hz
Object Classification CodeQ
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
ETIM 6EC000066 - Power contactor, AC switching
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
Manufacturer IDGJL1313209R5001

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
-