- TM-I 250/115-230 P
The ABB TM-I 250/115-230 P is a one-phase control transformer with electrically separated primary and secondary windings. Primary voltage is 230-400 ±15 V AC; secondary voltage is 115-230 V AC at 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and power loss is 38 W. The conductor is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 100 mm wide, 105 mm high, and 110 mm deep. Applicable standards are EN 61558-2-2, EN 61558-2-4, UL 506, and CSA C22-2-N66. RoHS information is available separately.
- TM-I 2500/115-230 P
ABB TM-I 2500/115-230 P is a single-phase control and isolating transformer. Primary voltage is 230-400 ±15 V AC; secondary voltage is 115-230 V AC at 50/60 Hz. Power supply is 2500 V·A, power loss 100 W, rated insulation voltage (Ui) 4.8 kV, insulation class F, copper conductor, cable cross-section 6 mm², fuse type aM. Maximum ambient temperature is 40 °C. Dimensions are 200 mm width, 191 mm height, 230 mm depth. Standards: EN 61558-2-2, EN 61558-2-4, UL 506, CSA C22-2-N66. Manufacturer ID 2CSM204363R0801. ETIM 8 and ETIM 9: EC002486 - One-phase control transformer.
- TM-I 320/115-230 P
ABB TM-I 320/115-230 P transformer, manufacturer ID 2CSM204493R0801, classified as a one-phase control transformer (ETIM EC002486). Primary voltage is 230-400 ±15 V AC; secondary voltage is 115-230 V AC at 50/60 Hz. Power supply is 320 V·A, power loss 36 W, rated insulation voltage (Ui) 4.8 kV, insulation class F. Conductor material is copper with 6 mm² cable cross-section and aM fuse type. Maximum ambient temperature is 40 °C. Dimensions are 123 mm width, 91 mm height, 102 mm depth. Standards: EN 61558-2-2, EN 61558-2-4, UL 506, CSA C22-2-N66. RoHS information applies.
- TM-I 400/115-230 P
The ABB TM-I 400/115-230 P is a single-phase isolating transformer classified under ETIM 8 and ETIM 9 as EC002486, one-phase control transformer. It accepts a primary voltage of 230-400 ±15 V AC and delivers a secondary voltage of 115-230 V AC at 50/60 Hz, with a power supply rating of 400 V·A and power loss of 41 W. Rated insulation voltage is 4.8 kV, insulation class is F, conductor material is copper, and cable cross-section is 6 mm². It is built to EN 61558-2-2, EN 61558-2-4, UL 506, and CSA C22-2-N66. Maximum ambient temperature is 40 °C. Dimensions are 123 mm wide, 104 mm high, and 112 mm deep. Fuse type is aM. RoHS information is available separately.
- TM-I 50/115-230 P
ABB TM-I 50/115-230 P transformer, classified as a transformer part and identified by manufacturer ID 2CSM204583R0801. It is a single-phase control transformer with a 50 V·A power supply, primary voltage 230-400 ±15 V AC, secondary voltage 115-230 V AC, and rated frequency 50/60 Hz. Rated insulation voltage is 4.8 kV, insulation class F, conductor material copper, cable cross-section 6 mm², power loss 9 W, and fuse type aM. Maximum ambient temperature is 40 °C. Standards: EN 61558-2-2, EN 61558-2-4, UL 506, CSA C22-2-N66. Dimensions are 80 mm width, 69 mm height, 74 mm depth. ETIM 8 and ETIM 9: EC002486 one-phase control transformer. RoHS information applies.
- TM-I 630/115-230 P
ABB TM-I 630/115-230 P is a one-phase control transformer for transformer parts applications. It provides a 630 V·A power supply with a primary voltage of 230-400 ±15 V AC and a secondary voltage of 115-230 V AC at 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and power loss is 47 W. The conductor material is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 154 mm width, 122 mm height, and 126 mm depth. Applicable standards include EN 61558-2-2, EN 61558-2-4, UL 506, and CSA C22-2-N66. Environmental information is provided in the RoHS information.
- TM-S 100/12-24 P
ABB TM-S 100/12-24 P transformer, category transformer parts. Manufacturer ID 2CSM207163R0801. Primary voltage 230-400 ±15 V AC; secondary voltage 12-24 V AC; rated frequency 50/60 Hz. Power supply 100 V·A; power loss 15 W; rated insulation voltage (Ui) 4.8 kV; insulation class F. Conductor material copper; cable cross-section 6 mm²; fuse type aM. Ambient temperature max. 40 °C. Standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66. Dimensions: width 200 mm, height 87 mm, depth 87 mm. ETIM 8 and ETIM 9: EC002486 one-phase control transformer. Environmental information: see RoHS information.
- TM-S 1000/12-24 P
ABB TM-S 1000/12-24 P transformer, manufacturer ID 2CSM260093R0801. Primary voltage 230-400 ±15 V AC, secondary voltage 12-24 V AC, rated frequency 50/60 Hz, power supply 1000 V·A, power loss 60 W. Rated insulation voltage (Ui) 4.8 kV, insulation class F, copper conductor, cable cross-section 6 mm², fuse type aM. Ambient temperature max. 40 °C. Dimensions: 155 mm width, 166 mm height, 168 mm depth. Standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66. ETIM 8 and ETIM 9: EC002486 one-phase control transformer. RoHS information available separately.