- TM-S 1000/12-24 P
ABB TM-S 1000/12-24 P transformer, manufacturer ID 2CSM260093R0801. Primary voltage 230-400 ±15 V AC, secondary voltage 12-24 V AC, rated frequency 50/60 Hz, power supply 1000 V·A, power loss 60 W. Rated insulation voltage (Ui) 4.8 kV, insulation class F, copper conductor, cable cross-section 6 mm², fuse type aM. Ambient temperature max. 40 °C. Dimensions: 155 mm width, 166 mm height, 168 mm depth. Standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66. ETIM 8 and ETIM 9: EC002486 one-phase control transformer. RoHS information available separately.
- TM-S 160/12-24 P
ABB TM-S 160/12-24 P is a single-phase control transformer for transformer parts applications. It provides a 160 V·A power supply with a primary voltage of 230-400 ±15 V AC and a secondary voltage of 12-24 V AC at 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and power loss is 19 W. The conductor material is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 100 mm width, 105 mm height, and 90 mm depth, with a net weight of 2.685 g. Applicable standards are EN 61558-2-2, EN 61558-2-6, UL506, and CSA C22-2-N66. Manufacturer ID: 2CSM202073R0801.
- TM-S 160/24-48 P
The ABB TM-S 160/24-48 P is a single-phase control transformer in the ABB transformer parts category. It has a rated power of 160 V·A, a primary voltage of 230-400 ±15 V AC, and a secondary voltage of 24-48 V AC at 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and power loss is 19 W. Conductors are copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. The transformer conforms to EN 61558-2-2, EN 61558-2-6, UL506, and CSA C22-2-N66. Net dimensions are 100 mm width, 89 mm height, and 90 mm depth. The manufacturer ID is 2CSM204633R0801.
- TM-S 1600/12-24 P
The ABB TM-S 1600/12-24 P is a single-phase control transformer for voltage control. Its primary voltage is 230-400 ±15 V AC and its secondary voltage is 12-24 V AC at a rated frequency of 50/60 Hz. Power supply is 1600 V·A, with a power loss of 70 W. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and the conductor material is copper with a 6 mm² cable cross-section. The fuse type is aM. Maximum ambient temperature is 40 °C. Applicable standards are EN 61558-2-2, EN 61558-2-6, UL506, and CSA C22-2-N66. Dimensions are 200 mm width, 163 mm height, and 200 mm depth. Environmental information: see RoHS Information.
- TM-S 200/12-24 P
The ABB TM-S 200/12-24 P is a single-phase control transformer for supplying safety extra-low voltage circuits. Primary voltage is 230-400 ±15 V AC and secondary voltage is 12-24 V AC at 50/60 Hz, with a power supply of 200 V·A. Rated insulation voltage (Ui) is 4.8 kV, insulation class is F, and power loss is 21 W. The conductor material is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Applicable standards are EN 61558-2-2, EN 61558-2-6, UL506, and CSA C22-2-N66. Dimensions are 100 mm width, 89 mm height, and 90 mm depth. Manufacturer ID: 2CSM260043R0801.
- TM-S 2000/12-24 P
ABB TM-S 2000/12-24 P transformer, manufacturer ID 2CSM260073R0801, is a one-phase control transformer (ETIM EC002486) rated 2000 V·A. Primary voltage is 230-400 ±15 V AC; secondary voltage is 12-24 V AC at 50/60 Hz. Rated insulation voltage (Ui) is 4.8 kV, insulation class F, conductor material copper, cable cross-section 6 mm², fuse type aM, power loss 85 W, maximum ambient temperature 40 °C. It conforms to EN 61558-2-2, EN 61558-2-6, UL506, and CSA C22-2-N66. Dimensions are 200 mm width, 181 mm height, 230 mm depth; net weight 25.5 g. RoHS information is available separately.
- TM-S 250/12-24 P
ABB TM-S 250/12-24 P transformer, manufacturer ID 2CSM260113R0801, is a one-phase control transformer (ETIM EC002486). It accepts a primary voltage of 230-400 ±15 V AC at 50/60 Hz and provides a secondary voltage of 12-24 V AC, with a power supply of 250 V·A. Rated insulation voltage (Ui) is 4.8 kV, insulation class F, conductor material copper, and cable cross-section 6 mm². Maximum ambient temperature is 40 °C. Applicable standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66. Dimensions are 100 mm width, 105 mm height, 110 mm depth. Power loss is 38 W. Fuse type aM. See RoHS Information for environmental data.
- TM-S 250/24-48 P
ABB TM-S 250/24-48 P is a single-phase control transformer with manufacturer ID 2CSM204683R0801. It accepts a primary voltage of 230-400 ±15 V AC and provides a secondary voltage of 24-48 V AC at 50/60 Hz, with a power supply rating of 250 V·A. Rated insulation voltage is 4.8 kV, insulation class is F, and power loss is 21 W. The conductor is copper with a 6 mm² cable cross-section, and the fuse type is aM. Maximum ambient temperature is 40 °C. Dimensions are 100 mm width, 105 mm height, and 110 mm depth. Standards: EN 61558-2-2, EN 61558-2-6, UL506, CSA C22-2-N66. RoHS information is available separately.