- B7-30-10-03
The ABB B7-30-10-03 is a three-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. It measures 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.175 kg. The rated control circuit voltage is 48 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C according to IEC 60947-4-1. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, 5.5 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Mechanical durability is 10,000,000 cycles. Terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm². The contactor mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, and IEC 60335-2-40 A2L.
- B7-30-10-80
The ABB B7-30-10-80 is a 3-pole mini contactor with 3 NO main contacts and 1 NO auxiliary contact. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. The control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. Screw terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm². Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B7-30-10-84
The ABB B7-30-10-84 is a compact 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its coil is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for the main and auxiliary circuits. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- B7-30-10-85
ABB B7-30-10-85 mini contactor, 3-pole with 3 main NO contacts and 1 auxiliary NO contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Conventional free-air thermal current (Ith) is 20 A. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.175 kg. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors, 9 mm stripping length, 0.8 to 1.1 N·m tightening torque. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- B7-30-10-F-01
ABB B7-30-10-F-01 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Coil voltage is 24 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits and 250 V DC for the auxiliary circuit. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, 3 kW at 230 V and 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715, TH35-15 and TH35-7.5. Ambient operating temperature -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-10-F-02
ABB B7-30-10-F-02 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight is 0.17 kg. The control circuit is rated 42 V AC with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC; rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Terminal degree of protection is IP20. Mechanical durability is 10,000,000 cycles. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-10-F-03
ABB mini contactor, display model B7-30-10-F-03. Three-pole AC contactor with three main normally open contacts and one auxiliary normally open contact. Rated control circuit voltage is 48 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V for three-phase loads. Dimensions are 52.5 mm net width, 57.5 mm net height, and 46.7 mm net depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-10-F-80
ABB B7-30-10-F-80 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated control circuit voltage is 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated insulation voltage is 690 V per UL/CSA and 600 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.