- B7-30-10-80
The ABB B7-30-10-80 is a 3-pole mini contactor with 3 NO main contacts and 1 NO auxiliary contact. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, weighing 0.175 kg. The control circuit voltage is 220 to 240 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V and 5.5 kW at 400 V and 500 V, three-phase. Rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. Screw terminals accept rigid conductors from 1 to 4 mm² and flexible conductors from 1 to 2.5 mm². Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715.
- B7-30-10-84
The ABB B7-30-10-84 is a compact 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Its coil is rated 110 to 127 V AC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. Rated operational voltage is 690 V AC for the main and auxiliary circuits. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep, with a net weight of 0.175 kg. It mounts on TH35-15 or TH35-7.5 DIN rail according to IEC 60715.
- B7-30-10-85
ABB B7-30-10-85 mini contactor, 3-pole with 3 main NO contacts and 1 auxiliary NO contact. Rated control circuit voltage 380 to 415 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Conventional free-air thermal current (Ith) is 20 A. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.175 kg. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors, 9 mm stripping length, 0.8 to 1.1 N·m tightening torque. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- B7-30-10-F-01
ABB B7-30-10-F-01 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Coil voltage is 24 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits and 250 V DC for the auxiliary circuit. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase, 3 kW at 230 V and 690 V three-phase. Dimensions are 52.5 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715, TH35-15 and TH35-7.5. Ambient operating temperature -25 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-10-F-02
ABB B7-30-10-F-02 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight is 0.17 kg. The control circuit is rated 42 V AC with coil operating limits of 0.85 to 1.1 x Uc according to IEC 60947-4-1 for AC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC; rated insulation voltage is 690 V, and rated impulse withstand voltage is 6 kV for main and auxiliary circuits. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V three-phase. Terminal degree of protection is IP20. Mechanical durability is 10,000,000 cycles. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-10-F-03
ABB mini contactor, display model B7-30-10-F-03. Three-pole AC contactor with three main normally open contacts and one auxiliary normally open contact. Rated control circuit voltage is 48 V AC; coil operating limits per IEC 60947-4-1 for AC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 5.5 kW at 400 V and 500 V for three-phase loads. Dimensions are 52.5 mm net width, 57.5 mm net height, and 46.7 mm net depth; net weight 0.17 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- B7-30-10-F-80
ABB B7-30-10-F-80 mini contactor, 3-pole, with 3 NO main contacts and 1 NO auxiliary contact. Rated control circuit voltage is 220 to 240 V AC; coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 3 kW at 230 V three-phase, 5.5 kW at 400 V three-phase, and 5.5 kW at 500 V three-phase. Rated insulation voltage is 690 V per UL/CSA and 600 V. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. DIN-rail mounting per IEC 60715. Mechanical durability is 10,000,000 cycles. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- B7-30-10-F-84
ABB B7-30-10-F-84 is a 3-pole mini contactor with three normally open main contacts and one normally open auxiliary contact. The control circuit voltage is 110 to 127 V AC. Rated operational voltage is 690 V AC for the main and auxiliary circuits, and 220 V DC for the main circuit. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 690 V for both temperatures. Rated operational power AC-3 is 3 kW at 230 V, 5.5 kW at 400 V and 500 V, and 3 kW at 690 V three phase. Dimensions are 52.5 mm wide, 57.5 mm high, and 46.7 mm deep; net weight 0.17 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -25 to +55 °C.