- VBC6-30-01-2.4-51
The ABB VBC6-30-01-2.4-51 is a compact DC-operated miniature reversing IEC contactor with a 24 VDC coil and three normally open main contacts. It is rated for three-phase motor loads up to 4 kW at 400 V and 500 V in AC-3. The control circuit accepts 17 to 32 V DC, with coil operating limits of 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C. The contactor measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. It provides screw terminals, DIN rail mounting per IEC 60715, and a mechanical durability of 10,000,000 cycles. It conforms to IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VBC6-30-01-F-01
ABB invertible contactor VBC6-30-01-F-01, manufacturer ID GJL1213903R0011. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated control circuit voltage is 24 V DC, with coil operating limits of 0.85 to 1.1 x Uc for DC supply at ambient temperatures up to 55 °C. Main circuit rated operational voltage is 690 V AC; rated impulse withstand voltage is 6 kV. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Rated operational current AC-1 is 20 A at 40 °C for 220/240 V and 380/440 V. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.345 kg. DIN-rail mounting per IEC 60715; terminal degree of protection IP20.
- VBC6-30-01-P-01
ABB invertible contactor VBC6-30-01-P-01 (manufacturer ID GJL1213909R0011) is a 3-pole device with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, with main circuit rated impulse withstand voltage 6 kV. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight is 0.345 kg. Terminal degree of protection is IP20. DIN-rail mounting per IEC 60715. Operation ambient range is -20 to +55 °C.
- VBC6-30-01-P-1.481
ABB invertible contactor VBC6-30-01-P-1.481, manufacturer ID GJL1213909R8011. Three-pole device with three main normally open contacts and one auxiliary normally closed contact. Control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, with main circuit rated impulse withstand voltage 6 kV. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature range is -20 to +55 °C.
- VBC6-30-01*24V DC
ABB VBC6-30-01*24V DC is an industrial catalog item. Key specifications include Package: Box-packed. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- VBC6-30-10-01
ABB VBC6-30-10-01 invertible contactor, manufacturer ID GJL1213901R0101. Three-pole device with three NO main contacts and one NO auxiliary contact. Control circuit rated 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV. Dimensions are 96.2 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.355 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VBC6-30-10-03
ABB VBC6-30-10-03 invertible contactor, manufacturer ID GJL1213901R0103. Three-pole device with three NO main contacts and one NO auxiliary contact, screw terminals, and mechanical interlock. Main circuit rated operational voltage is 690 V AC or 220 V DC; rated impulse withstand voltage is 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Control circuit voltage is 60 V DC. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg.
- VBC6-30-10-04
ABB VBC6-30-10-04 invertible contactor, manufacturer ID GJL1213901R0104. Three-pole device with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 110 to 125 V DC, with coil operating limits 0.85 to 1.1 x Uc per IEC 60947-4-1 at temperatures up to 55 °C. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 mm W x 57.5 mm H x 46.7 mm D; net weight 0.355 kg. DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operating temperature -20 to +55 °C.