- VBC6-30-01-P-1.481
ABB invertible contactor VBC6-30-01-P-1.481, manufacturer ID GJL1213909R8011. Three-pole device with three main normally open contacts and one auxiliary normally closed contact. Control circuit voltage is 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Rated operational voltage is 690 V AC for main and auxiliary circuits, with main circuit rated impulse withstand voltage 6 kV. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg. Mechanical durability is 10,000,000 cycles. Ambient operating temperature range is -20 to +55 °C.
- VBC6-30-01*24V DC
ABB VBC6-30-01*24V DC is an industrial catalog item. Key specifications include Package: Box-packed. The exact model designation and listed values keep the item identifiable for engineering comparison, sourcing review, and verification against project documentation.
- VBC6-30-10-01
ABB VBC6-30-10-01 invertible contactor, manufacturer ID GJL1213901R0101. Three-pole device with three NO main contacts and one NO auxiliary contact. Control circuit rated 24 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV. Dimensions are 96.2 mm wide, 57.5 mm high, 46.7 mm deep; net weight 0.355 kg. Mechanical durability is 10,000,000 cycles. Terminals are IP20. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VBC6-30-10-03
ABB VBC6-30-10-03 invertible contactor, manufacturer ID GJL1213901R0103. Three-pole device with three NO main contacts and one NO auxiliary contact, screw terminals, and mechanical interlock. Main circuit rated operational voltage is 690 V AC or 220 V DC; rated impulse withstand voltage is 6 kV. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Control circuit voltage is 60 V DC. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg.
- VBC6-30-10-04
ABB VBC6-30-10-04 invertible contactor, manufacturer ID GJL1213901R0104. Three-pole device with 3 NO main contacts and 1 NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 110 to 125 V DC, with coil operating limits 0.85 to 1.1 x Uc per IEC 60947-4-1 at temperatures up to 55 °C. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, 3 kW at 690 V, three-phase. Dimensions 96.2 mm W x 57.5 mm H x 46.7 mm D; net weight 0.355 kg. DIN rail mounting per IEC 60715. Mechanical durability 10,000,000 cycles. Ambient operating temperature -20 to +55 °C.
- VBC6-30-10-05
ABB VBC6-30-10-05 invertible contactor, manufacturer ID GJL1213901R0105. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage 220 to 240 V DC; coil operating limits per IEC 60947-4-1 for DC supply are 0.85 to 1.1 x Uc at ambient temperature up to 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220 to 240 V and 380 to 440 V, and 6 A at 690 V. Dimensions 96.2 x 57.5 x 46.7 mm, 0.355 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VBC6-30-10-07
ABB invertible contactor VBC6-30-10-07, manufacturer ID GJL1213901R0107. Three-pole device with three main NO contacts, one auxiliary NO contact, and a 12 V DC control coil. Rated operational voltage is 690 V AC for main and auxiliary circuits. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors, tightening torque 0.8 to 1.1 N·m. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C.
- VBC6-30-10-1.4-81
The ABB VBC6-30-10-1.4-81 is a 3-pole invertible contactor with a 24 V DC control circuit voltage and three normally open main contacts. Its rated operational power in AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both 40 °C and 55 °C. The unit measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighs 0.355 kg, and offers IP20 protection on main, auxiliary, and control circuit terminals. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Manufacturer ID: GJL1213901R8101.