- VB6-30-01-F-01
ABB invertible contactor VB6-30-01-F-01, manufacturer ID GJL1211903R0011. Three-pole device with three main NO contacts, no main NC contacts, and one auxiliary NC contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage is 24 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both temperatures for 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-30-01-F-80
The ABB VB6-30-01-F-80 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.345 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit voltage is 220 to 240 V AC. Mechanical durability is 10,000,000 cycles. Ambient operating temperature is -20 to +55 °C.
- VB6-30-01-P-01
ABB VB6-30-01-P-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 24 V AC, with coil operating limits of 0.85 to 1.1 x Uc at ambient temperatures up to 55 °C according to IEC 60947-4-1. Main circuit rated operational voltage is 690 V AC, rated impulse withstand voltage 6 kV, and rated insulation voltage 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, and 2.2 kW at 230 V. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth, with a net weight of 0.345 kg. DIN-rail mounting is supported per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-30-01-P-02
ABB invertible contactor VB6-30-01-P-02, manufacturer ID GJL1211909R0012. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Main circuit rated operational voltage is 690 V AC or 220 V DC; auxiliary circuit is 690 V AC or 250 V DC. Rated control circuit voltage is 42 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Rated impulse withstand voltage is 6 kV. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg.
- VB6-30-01-P-80
ABB invertible contactor VB6-30-01-P-80, manufacturer ID GJL1211909R8010. Three-pole device with three NO main contacts and one NC auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 220 to 240 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three-phase. Dimensions 96.2 x 57.5 x 47.7 mm, net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VB6-30-10-01
The ABB VB6-30-10-01 is a 3-pole invertible contactor with three normally open main contacts and one normally open auxiliary contact. Its 24 V AC control circuit coil operates within 0.85 to 1.1 times Uc at ambient temperatures up to 55 °C, in accordance with IEC 60947-4-1. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 16 A at the same voltages at 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. The contactor measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, weighs 0.355 kg, and mounts on TH35-15 or TH35-7.5 DIN rail to IEC 60715.
- VB6-30-10-03
ABB VB6-30-10-03 invertible contactor, manufacturer ID GJL1211901R0103. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage is 48 V AC. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three phase. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg.
- VB6-30-10-80
The ABB VB6-30-10-80 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. Its rated control circuit voltage is 220 to 240 V AC, and the rated operational power in AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Rated operational voltage is 690 V AC for main and auxiliary circuits. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.355 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Ambient operating temperature is -20 to +55 °C, and maximum operating altitude is 2000 m.