- VB6-30-10-03
ABB VB6-30-10-03 invertible contactor, manufacturer ID GJL1211901R0103. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated control circuit voltage is 48 V AC. Rated operational voltage: main circuit 690 V AC / 220 V DC, auxiliary circuit 690 V AC / 250 V DC. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at both 40 °C and 55 °C for 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V three phase. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg.
- VB6-30-10-80
The ABB VB6-30-10-80 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. Its rated control circuit voltage is 220 to 240 V AC, and the rated operational power in AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V for three-phase loads. Rated operational voltage is 690 V AC for main and auxiliary circuits. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.355 kg. It mounts on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Ambient operating temperature is -20 to +55 °C, and maximum operating altitude is 2000 m.
- VB6-30-10-85
The ABB VB6-30-10-85 is a 3-pole invertible contactor with three NO main contacts and one NO auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and a rated insulation voltage of 690 V. The control circuit coil operates at 380 to 415 V AC. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V, and 4 kW at 500 V, three phase. Mechanical durability is 10,000,000 cycles. Terminals accept rigid conductors from 1 to 4 mm² and are protected to IP20. Mounting is on TH35-15 or TH35-7.5 DIN rail per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- VB6-30-10-F-01
ABB invertible contactor VB6-30-10-F-01, manufacturer ID GJL1211903R0101. Three-pole (3 NO main contacts) with one NO auxiliary contact. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Control circuit voltage 24 V AC. Coil operating limits acc. to IEC 60947-4-1: 0.85 to 1.1 x Uc at up to 55 °C. Dimensions 96.2 x 57.5 x 46.7 mm, 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1.
- VB6-30-10-F-80
ABB invertible contactor VB6-30-10-F-80, manufacturer ID GJL1211903R8100. Three main contacts NO and one auxiliary contact NO, rated control circuit voltage 220 to 240 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three phase, 4 kW at 400 V three phase, 4 kW at 500 V three phase, and 3 kW at 690 V three phase. Rated insulation voltage is 690 V, rated impulse withstand voltage 6 kV, and conventional free-air thermal current 20 A. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, with a net weight of 0.345 kg. DIN-rail mounting per IEC 60715. Ambient operating temperature is -20 to +55 degrees C. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, and IEC/EN 60947-5-1.
- VB6-30-10-P-01
ABB invertible contactor VB6-30-10-P-01, manufacturer ID GJL1211909R0101. Three-pole device with three normally open main contacts and one normally open auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage is 24 V AC. Rated operational power AC-3: 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. DIN-rail mounting per IEC 60715. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6-30-10-P-85
ABB invertible contactor, model VB6-30-10-P-85, manufacturer ID GJL1211909R8105. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions: 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-40-00-01
The ABB VB6-40-00-01 is a four-pole invertible contactor with four normally open main contacts and no auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. Main circuit ratings include 690 V AC and 220 V DC operational voltage, 6 kV impulse withstand, and 690 V insulation voltage. AC-1 operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 24 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1. Mechanical durability is 10,000,000 cycles.