- VB6-30-10-P-85
ABB invertible contactor, model VB6-30-10-P-85, manufacturer ID GJL1211909R8105. Three-pole device with three NO main contacts and one NO auxiliary contact. Rated operational voltage: main circuit 690 V AC / 220 V DC; auxiliary circuit 690 V AC / 250 V DC. Rated control circuit voltage 380 to 415 V AC. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V, three-phase. Dimensions: 96.2 mm width, 57.5 mm height, 47.7 mm depth; net weight 0.345 kg. DIN rail mounting per IEC 60715. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6-40-00-01
The ABB VB6-40-00-01 is a four-pole invertible contactor with four normally open main contacts and no auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. Main circuit ratings include 690 V AC and 220 V DC operational voltage, 6 kV impulse withstand, and 690 V insulation voltage. AC-1 operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. AC-3 operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. The control circuit is 24 V AC, with coil operating limits of 0.85 to 1.1 times Uc according to IEC 60947-4-1. Mechanical durability is 10,000,000 cycles.
- VB6-40-00-80
The ABB VB6-40-00-80 is a 4-pole invertible contactor with four NO main contacts and no NC main or auxiliary contacts. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated operational power AC-3 is 4 kW at 400 V and 500 V. The control circuit voltage is 220 to 240 V AC. Terminals are IP20.
- VB6-40-00-P-80
ABB invertible contactor, display model VB6-40-00-P-80, manufacturer ID GJL1211909R8000. Four-pole unit with four normally open main contacts and no normally closed main or auxiliary contacts. Main circuit rated operational voltage is 690 V AC and 220 V DC; rated insulation voltage is 690 V according to UL/CSA and 600 V. Rated impulse withstand voltage for the main circuit is 6 kV. Rated operational current AC-1 is 12 A at 220/240 V and 380/440 V at both 40 °C and 55 °C, and 6 A at 690 V at both 40 °C and 55 °C. Rated operational power AC-3 is 2.2 kW at 230 V three phase, 4 kW at 400 V and 500 V three phase, and 3 kW at 690 V three phase. Control circuit voltage is 220 to 240 V AC. Dimensions are 96.2 mm width, 57.5 mm height, and 47.7 mm depth; net weight 0.345 kg.
- VB6A-30-01-01
The ABB VB6A-30-01-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC, with a rated impulse withstand voltage of 6 kV and a conventional free-air thermal current of 20 A. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 24 V AC. Coil operating limits are 0.85 to 1.1 times Uc at ambient temperatures up to 55 degrees C, in accordance with IEC 60947-4-1. Terminal protection is IP20.
- VB6A-30-01-02
ABB VB6A-30-01-02 invertible contactor, 3-pole with 3 NO main contacts and 1 NC auxiliary contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated control circuit voltage is 42 V AC. Coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, weighing 0.355 kg. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6A-30-01-03
ABB invertible contactor VB6A-30-01-03, manufacturer ID GJL1211911R0013. Three main contacts NO and one auxiliary contact NC. Rated control circuit voltage 48 V AC. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Dimensions 96.2 mm x 57.5 mm x 46.7 mm; net weight 0.355 kg. DIN rail mounting per IEC 60715. Ambient operating temperature -20 to +55 °C. Standards include IEC/EN 60947-4-1.
- VB6A-30-01-80
ABB invertible contactor VB6A-30-01-80, manufacturer ID GJL1211911R8010. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 220 to 240 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V three-phase, 4 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, with rated impulse withstand voltage 6 kV for the main circuit. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg. Ambient operating temperature range is -20 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.