- VB6A-30-01-01
The ABB VB6A-30-01-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. It measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. The main circuit is rated 690 V AC, with a rated impulse withstand voltage of 6 kV and a conventional free-air thermal current of 20 A. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. The control circuit voltage is 24 V AC. Coil operating limits are 0.85 to 1.1 times Uc at ambient temperatures up to 55 degrees C, in accordance with IEC 60947-4-1. Terminal protection is IP20.
- VB6A-30-01-02
ABB VB6A-30-01-02 invertible contactor, 3-pole with 3 NO main contacts and 1 NC auxiliary contact. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Rated control circuit voltage is 42 V AC. Coil operating limits per IEC 60947-4-1 are 0.85 to 1.1 x Uc at temperatures up to 55 °C. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth, weighing 0.355 kg. Mechanical durability is 10,000,000 cycles. Terminal protection is IP20. Standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, and UL 60947-4-1.
- VB6A-30-01-03
ABB invertible contactor VB6A-30-01-03, manufacturer ID GJL1211911R0013. Three main contacts NO and one auxiliary contact NC. Rated control circuit voltage 48 V AC. Rated operational current AC-1 is 20 A at 220/240 V and 380/440 V at 40 °C, and 6 A at 690 V at 40 °C. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Rated insulation voltage 690 V; rated impulse withstand voltage 6 kV. Dimensions 96.2 mm x 57.5 mm x 46.7 mm; net weight 0.355 kg. DIN rail mounting per IEC 60715. Ambient operating temperature -20 to +55 °C. Standards include IEC/EN 60947-4-1.
- VB6A-30-01-80
ABB invertible contactor VB6A-30-01-80, manufacturer ID GJL1211911R8010. Three-pole device with three normally open main contacts and one normally closed auxiliary contact. Rated control circuit voltage is 220 to 240 V AC. Rated operational power AC-3 is 2.2 kW at 230 V three-phase, 4 kW at 400 V three-phase, 4 kW at 500 V three-phase, and 3 kW at 690 V three-phase. Rated insulation voltage is 690 V, with rated impulse withstand voltage 6 kV for the main circuit. Mechanical durability is 10,000,000 cycles. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight 0.355 kg. Ambient operating temperature range is -20 to +55 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6A-30-01-84
The ABB VB6A-30-01-84 is an invertible contactor with three main normally open contacts and one auxiliary normally closed contact. It has a rated control circuit voltage of 110 to 127 V AC and operates on main circuit voltages up to 690 V AC. Rated operational power is 4 kW at 400 V and 500 V three-phase, and 2.2 kW at 230 V three-phase. The contactor measures 96.2 mm wide, 57.5 mm high, and 46.7 mm deep, and weighs 0.355 kg. It supports DIN rail mounting per IEC 60715 and offers mechanical durability of 10,000,000 cycles. Ambient operating temperature range is -20 to +55 degrees Celsius.
- VB6A-30-01-85
ABB invertible contactor VB6A-30-01-85 (manufacturer ID GJL1211911R8015). Three-pole device with three NO main contacts, one NC auxiliary contact, and a control circuit rated 380 to 415 V AC. Rated operational voltage is 690 V AC for main and auxiliary circuits, 220 V DC main and 250 V DC auxiliary. Rated operational power AC-3 is 4 kW at 400 V and 500 V three-phase, 2.2 kW at 230 V, and 3 kW at 690 V. Rated operational current AC-1 is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.355 kg. Screw terminals accept rigid 1 to 4 mm² and flexible 1 to 2.5 mm² conductors. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- VB6A-30-01-F-01
ABB VB6A-30-01-F-01 is a 3-pole invertible contactor with three normally open main contacts and one normally closed auxiliary contact. The control circuit is rated 24 V AC at 50 Hz, 60 Hz, or 400 Hz. Main circuit ratings include 690 V AC and 220 V DC, with a rated impulse withstand voltage of 6 kV and rated insulation voltage of 690 V. AC-1 operational current is 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V, and 6 A at 690 V for both temperatures. AC-3 operational power is 2.2 kW at 230 V, 4 kW at 400 V and 500 V, and 3 kW at 690 V. Dimensions are 96.2 mm width, 57.5 mm height, and 46.7 mm depth; net weight is 0.345 kg.
- VB6A-30-01-F-80
ABB invertible contactor, display model VB6A-30-01-F-80, manufacturer ID GJL1211913R8010. Three-pole (3P) device with three normally open main contacts and one normally closed auxiliary contact. Rated operational voltage: main circuit 690 V AC and 220 V DC; auxiliary circuit 690 V AC and 250 V DC. Rated control circuit voltage 220 to 240 V AC. Rated operational power AC-3: 2.2 kW at 230 V three-phase, 4 kW at 400 V and 500 V three-phase, and 3 kW at 690 V three-phase. Rated operational current AC-1: 20 A at 40 °C and 16 A at 55 °C for 220/240 V and 380/440 V; 6 A at 40 °C and 55 °C for 690 V. Dimensions 96.2 mm width, 57.5 mm height, 46.7 mm depth; net weight 0.345 kg.