- ESB63-40N-02
ABB building contactor ESB63-40N-02, manufacturer ID 1SAE351111R0240. Four-pole (4 NO main contacts, no auxiliary contacts) installation contactor for distribution boards. Main circuit rated operational voltage 220 V DC and 400 V AC; rated control circuit voltage 42 V. Rated operational current 63 A at AC-1, 63 A at AC-7a, and 30 A at AC-3 (230 V single-phase and 400 V three-phase). Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3, IP20. Dimensions 54 x 85 x 65 mm, 0.405 kg, 3.0 modular spacings. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-40N-03
ABB building contactor ESB63-40N-03, manufacturer ID 1SAE351111M0340. Four-pole (4 NO main contacts, no auxiliary contacts), rated operational current AC-1 63 A and AC-7a 63 A; AC-3 30 A at 230 V single phase and 30 A at 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 48 V. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.405 kg. IP20, pollution degree 3, 3.0 modular spacings. Mechanical durability 1,000,000 cycles. Ambient air temperature -25 to +55 °C operation, -40 to +80 °C storage. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-40N-05
The ABB ESB63-40N-05 is a four-pole installation contactor for distribution boards, with four normally open main contacts and no auxiliary contacts. It is rated 63 A at AC-1 and AC-7a, and 30 A at AC-3 and AC-7b at 230 V single-phase and 400 V three-phase. Rated operational voltage is 220 V DC and 400 V AC on the main circuit, with a 240 V control circuit voltage. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.405 kg. It offers IP20 protection, 6 kV impulse withstand, 500 V insulation voltage, and 1,000,000 mechanical operating cycles. Applicable standards include IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, and UL 60947-4-1.
- ESB63-40N-06
ABB building contactor ESB63-40N-06, manufacturer ID 1SAE351111M0640. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 63 A; AC-3 (NO) 30 A at 230 V single phase and 30 A at 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 230 V. Rated frequency: control circuit 400 Hz, 50 Hz, 60 Hz, and DC; main circuit 50 Hz, 60 Hz, and DC. Rated insulation voltage 500 V, rated impulse withstand voltage 6 kV, pollution degree 3. Dimensions 54 mm wide, 85 mm high, 65 mm deep; net weight 0.405 kg. Degree of protection IP20. Ambient air temperature -25 to +55 °C operation, -40 to +80 °C storage.
- ESB63-40N-07
ABB building contactor ESB63-40N-07, manufacturer ID 1SAE351111R0740. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Rated operational current AC-1 (NO) 63 A; AC-3 (NO) 30 A at 230 V single phase and 400 V three phase. Rated operational voltage: main circuit 220 V DC and 400 V AC. Rated control circuit voltage 400 V. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 54 mm width, 85 mm height, 65 mm depth; weight 0.4 kg. Degree of protection IP20. Ambient air temperature: operation -25 to +55 degrees C, storage -40 to +80 degrees C. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L.
- ESB63-40N-08
The ABB ESB63-40N-08 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It is rated 63 A at AC-1 and AC-7a, and 30 A at AC-3 and AC-7b for single-phase 230 V and three-phase 400 V operation. Rated operational voltage is 220 V DC and 400 V AC in the main circuit; rated control circuit voltage is 415 V. Rated insulation voltage is 500 V and rated impulse withstand voltage is 6 kV. Dimensions are 54 mm wide, 85 mm high and 65 mm deep, weight 0.405 kg, IP20, with a maximum operating altitude of 2000 m. Standards listed include IEC/EN 60947-1, IEC/EN 60947-4-1 and IEC/EN 61095.
- ESB63-40N-14
The ABB ESB63-40N-14 is a four-pole building contactor with four normally open main contacts and no auxiliary contacts. It is rated 63 A AC-1 (NO) and 30 A AC-3 at 230 V single-phase and 400 V three-phase. Rated operational voltage is 220 V DC and 400 V AC in the main circuit; the rated control circuit voltage is 12 V. Dimensions are 54 mm wide, 85 mm high, and 65 mm deep, weighing 0.405 kg, with 3.0 modular spacings and IP20 protection. It operates from -25 to +55 °C and supports altitudes up to 2000 m. Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 61095, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L. Manufacturer ID: 1SAE351111M1440.
- ESB63-40N-DC-B
ABB ESB63-40N-DC-B building contactor, manufacturer ID 1SAE351221M0140. Four-pole installation contactor with four normally open main contacts and no auxiliary contacts. Main circuit rated 400 V AC at 50/60 Hz; control circuit rated 24 V DC. Rated operational current AC-1: 63 A at 55 °C air temperature near the contactor, 40 A at 85 °C, and 80 A at 85 °C with two poles in parallel. Rated operational power AC-1: 14.5 kW single-phase at 230 V and 43.6 kW three-phase at 400 V. Rated insulation voltage 500 V; rated impulse withstand voltage 6 kV. Dimensions 54 x 85 x 65 mm, 0.405 kg, IP20, DIN-rail mounting. Standards: GB/T 14048.4, IEC/EN 60947-4-1, IEC 60335-2-40 A2L.