Industrial Automation Parts. Prompt replies from real people.

ABB ESB63-40N-DC-B Installation Contactor

  • Warehouse stock, ready to ship
  • Fully genuine original parts
  • Free quotes within 24 hours
Get a Free Quote

Free quote · Reply within 24 hours

Last Updated: 11/25/2026

Q1Can you supply the ABB ESB63-40N-DC-B?

Yes. Stock comes from our own warehouse and a wide partner supplier network, including discontinued models — confirmed on enquiry.

Q2What will the ABB ESB63-40N-DC-B cost me?

Every enquiry gets the best market price we can offer at that moment, by email and WhatsApp together, usually within 24 hours.

Q3Are your products genuine?

Yes. Genuine original parts only — we refuse counterfeit or imitation products. Condition confirmed in writing.

Product Model
ESB63-40N-DC-B
Material Number
1SAE351221M0140
Manufacturer
ABB
Product ID
77022

Get a Free Quote

Request pricing and availability for ESB63-40N-DC-B.

More parts to source? Send your whole list in one enquiry

Key specifications

Product Net Weight
0.405 kg
Rated Operational Voltage
Main Circuit 400 V AC
Rated Control Circuit Voltage (Uc)
24 V DC
Rated Frequency (f)
Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)
for Air Temperature Near the Contactor = 85 °C, 2 Poles in Parallel 80 A for Air Temperature Near the Contactor = 55 °C 63 A for Air Temperature Near the Contactor = 85 °C 40 A
Rated Operational Power AC-1 (Pe)
(230 V) Single Phase, NO 14.5 kW (400 V) Three Phase, NO 43.6 kW
See all specifications

Product Highlights

  1. 24 V DC Control: Rated control circuit voltage is 24 V DC, with main circuit rated at 400 V AC and 50/60 Hz
  2. 4-Pole Configuration: Four normally open main contacts with no normally open or normally closed auxiliary contacts
  3. AC-1 Current Ratings: 63 A at 55 °C, 40 A at 85 °C, and 80 A at 85 °C with two poles in parallel
  4. AC-1 Power Ratings: 14.5 kW single-phase at 230 V and 43.6 kW three-phase at 400 V
  5. Ambient Temperature Range: Operating range of -40 to +40 °C at 0.75 to 1.1 Uc, -40 to +55 °C at 0.85 to 1.1 Uc, and holding at 0.5 Uc after pull-in from -40 to +85 °C
  6. Main Circuit Connections: Rigid conductors 1.5 to 25 mm², flexible conductors 1.5 to 16 mm², 13 mm stripping length, and 2.5 N·m tightening torque
  7. Mechanical Durability: 1,000,000 operating cycles
ESB63-40N-DC-B

Product Information

Technical Specifications

Specifications for ESB63-40N-DC-B

ParameterValue
Product Net Width54 mm
Product Net Height85 mm
Product Net Depth / Length65 mm
Product Net Weight0.405 kg
Rated Operational VoltageMain Circuit 400 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)for Air Temperature Near the Contactor = 85 °C, 2 Poles in Parallel 80 A for Air Temperature Near the Contactor = 55 °C 63 A for Air Temperature Near the Contactor = 85 °C 40 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NO 14.5 kW (400 V) Three Phase, NO 43.6 kW
Recommended Screw DriverControl Circuit Pozidriv 1 Main Circuit Pozidriv 2
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Insulation Voltage (Ui)500 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 500 V acc. to UL/CSA 500 V
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1.5 ... 16 mm² Flexible with Ferrule 2x 1.5 ... 10 mm² Flexible with Insulated Ferrule 1x 1.5 ... 16 mm² Flexible with Insulated Ferrule 2x 1.5 ... 10 mm² Flexible 2x 1.5 ... 10 mm² Flexible 1x 1.5 ... 16 mm² Rigid 1x 1.5 ... 25 mm² Rigid 2x 1.5 ... 10 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1.0 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 4.0 mm² Flexible 2x 1 ... 2.5 mm² Rigid 1x 1 ... 4 mm² Rigid 2x 1 ... 2.5 mm²
Tightening TorqueControl Circuit 0.9 N·m Main Circuit 2.5 N·m
Wire Stripping LengthControl Circuit 7 mm Main Circuit 13 mm
Degree of ProtectionIP20
Mechanical Durability1000000 cycle
Number of Poles4
Number of Auxiliary Contacts NC0
ParameterValue
Number of Auxiliary Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO4
Width in Number of Modular Spacings3.0
StandardsGB/T 14048.4 IEC/EN 60947-4-1 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSAMain Circuit 480 V AC
Connecting Capacity Main Circuit UL/CSASolid 16-4 AWG Stranded 16-4 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb Main Circuit 20 in·lb
Ambient Air TemperatureClose to Contactor for Holding with 0.5 Uc after Pull-in with 1.0 … 1.1 Uc -40 ... +85 °C Close to Contactor for Operation at 0.75 ... 1.1 Uc -40 ... +40 °C Close to Contactor for Operation at 0.85 ... 1.1 Uc -40 ... +55 °C Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWith 90% Main Pole Derating 5000 m With 95% Main Pole Derating 4000 m With 98% Main Pole Derating 3000 m Without Derating 2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Object Classification CodeQ
ETIM 5EC001653 - Installation contactor for distribution board
ETIM 6EC001653 - Installation contactor for distribution board
ETIM 7EC001653 - Installation contactor for distribution board
eClassV11.0 : 27142308
UNSPSC39121529
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
ETIM 8EC001653 - Installation contactor for distribution board
Manufacturer ID1SAE351221M0140

Specifications may change. Confirm the exact model, revision and offered condition with your quotation.

Need Help Checking This Part?

Ask about specifications, condition or a suitable alternative.

Contact Us on WhatsApp
WhatsApp
ABB ESB63-40N-DC-B Installation Contactor for EV Charging Applications