- DS201 K40 A300
The ABB DS201 K40 A300 is a 1P+N residual current circuit breaker (RCBO) with a K tripping characteristic and Type A residual current detection. It is rated 40 A with a 300 mA rated residual current, 240 V AC rated operational voltage per IEC 60898-1, and 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) is 10 kA, and rated service short-circuit breaking capacity (Ics) is 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The two-module DIN-rail device measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and operates from -25 to 55 degrees C. Screw terminals accept conductors from 0.75 to 25 square millimeters, with 2.8 N-m tightening torque.
- DS201 K6 A30
ABB DS201 K6 A30 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current. It is rated 6 A, 30 mA residual current, and 240 V AC according to IEC 60898-1, with a rated short-circuit capacity of 6 kA and rated ultimate short-circuit breaking capacity (Icu) of 10 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, and mounts on DIN rail. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and operates from -25 to 55 °C.
- DS201 K6 A300
The ABB DS201 K6 A300 is a leakage protection circuit breaker with a rated current of 6 A and a rated residual current of 300 mA. It has a K tripping characteristic and Type A residual current sensitivity. It is a two-pole device with one protected pole and occupies two modular spacings on a DIN rail. The rated operational voltage is 240 V AC according to IEC 60898-1, and the rated frequency is 50 to 60 Hz. The rated short-circuit capacity is 6 kA, and the rated ultimate short-circuit breaking capacity is 10 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. The product measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 K8 A30
ABB DS201 K8 A30 is a 1P+N leakage protection circuit breaker (RCBO) with a K tripping characteristic and Type A residual current. Rated current is 8 A, rated residual current 30 mA, rated operational voltage 240 V AC per IEC 60898-1, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 6 kA, rated ultimate short-circuit breaking capacity (Icu) 10 kA, and rated service short-circuit breaking capacity (Ics) 7.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, 69 mm depth, and 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 L C10 A10
The ABB DS201 L C10 A10 is a 1P+N leakage protection circuit breaker (RCBO) for single-phase circuits. It has a rated current of 10 A, rated residual current of 10 mA (Type A), tripping characteristic C, and rated operational voltage of 240 V AC per IEC 60898-1. Rated short-circuit capacity is 4.5 kA, with rated ultimate short-circuit breaking capacity (Icu) of 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Terminal tightening torque is 2.8 N·m.
- DS201 L C10 AC30
The ABB DS201 L C10 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 10 A and a rated residual current of 30 mA. It has a C tripping characteristic and Type AC residual current. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage of 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity is 6 kA, and rated service short-circuit breaking capacity is 4.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail.
- DS201 L C10 AC300
The ABB DS201 L C10 AC300 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It has a rated current of 10 A and a rated residual current of 300 mA. Rated ultimate short-circuit breaking capacity (Icu) is 6 kA, rated service short-circuit breaking capacity (Ics) is 4.5 kA, and rated short-circuit capacity is 4.5 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail.
- DS201 L C16 A10
The ABB DS201 L C16 A10 is a DIN-rail mounted leakage protection circuit breaker (RCBO) with a rated current of 16 A and a rated residual current of 10 mA, Type A. It has a C tripping characteristic and one protected pole in a two-pole, two-module housing measuring 35 mm wide, 85 mm high, and 69 mm deep. Rated operational voltage is 240 V AC per IEC 60898-1, rated frequency 50 to 60 Hz, rated short-circuit capacity 4.5 kA, and rated ultimate short-circuit breaking capacity 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Terminal tightening torque is 2.8 N·m, connecting capacity is 0.75 to 25 mm², and operating ambient temperature is -25 to 55 °C.