- DS201 L C10 AC30
The ABB DS201 L C10 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 10 A and a rated residual current of 30 mA. It has a C tripping characteristic and Type AC residual current. Rated operational voltage is 240 V according to IEC 60898-1, with rated insulation voltage of 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity is 6 kA, and rated service short-circuit breaking capacity is 4.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail.
- DS201 L C10 AC300
The ABB DS201 L C10 AC300 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. It has a rated current of 10 A and a rated residual current of 300 mA. Rated ultimate short-circuit breaking capacity (Icu) is 6 kA, rated service short-circuit breaking capacity (Ics) is 4.5 kA, and rated short-circuit capacity is 4.5 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail.
- DS201 L C16 A10
The ABB DS201 L C16 A10 is a DIN-rail mounted leakage protection circuit breaker (RCBO) with a rated current of 16 A and a rated residual current of 10 mA, Type A. It has a C tripping characteristic and one protected pole in a two-pole, two-module housing measuring 35 mm wide, 85 mm high, and 69 mm deep. Rated operational voltage is 240 V AC per IEC 60898-1, rated frequency 50 to 60 Hz, rated short-circuit capacity 4.5 kA, and rated ultimate short-circuit breaking capacity 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Terminal tightening torque is 2.8 N·m, connecting capacity is 0.75 to 25 mm², and operating ambient temperature is -25 to 55 °C.
- DS201 L C16 AC30
The ABB DS201 L C16 AC30 is a 1P+N leakage protection circuit breaker with a C tripping characteristic and Type AC residual current. Rated current is 16 A and rated residual current is 30 mA. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity is 6 kA, and rated service short-circuit breaking capacity is 4.5 kA. It is rated 240 V AC according to IEC 60898-1 and operates at 50 to 60 Hz. The device has two poles, one protected pole, two modular spacings, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with 200 g net weight. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 L C16 AC300
ABB DS201 L C16 AC300 is a 1P+N leakage protection circuit breaker with a rated current of 16 A and a rated residual current of 300 mA. It is a Type AC device with C tripping characteristic, 2 poles (1 protected), and 2 modular spacings for DIN-rail mounting. Rated operational voltage is 240 V AC according to IEC 60898-1, rated insulation voltage 500 V according to IEC/EN 60664-1, and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity 6 kA, and rated service short-circuit breaking capacity 4.5 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C. Screw terminals accept conductors from 0.75 to 25 square millimeters, with 2.8 N-m tightening torque.
- DS201 L C16 APR30
ABB DS201 L C16 APR30 is a 1P+N leakage protection circuit breaker (RCBO) for single-phase circuits, with 16 A rated current, 30 mA Type A residual current, and C tripping characteristic. It is rated 240 V AC according to IEC 60898-1 and 50 to 60 Hz, with 4.5 kA rated short-circuit capacity, 6 kA Icu, and 6 kA Inc. The APR characteristic is instantaneous with high immunity. It has two poles, one protected pole, two DIN-rail module spacings, screw terminals, 2.8 N·m tightening torque, and 35 x 85 x 69 mm dimensions. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Operating ambient air temperature is -25 to 55 °C; degree of protection is IP20/IP40.
- DS201 L C20 APR30
The ABB DS201 L C20 APR30 is a two-pole leakage protection circuit breaker with one protected pole and a C tripping characteristic. It is rated 20 A, 240 V AC per IEC 60898-1, with 30 mA Type A residual current sensitivity. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity (Icu) is 6 kA, and rated conditional short-circuit current (Inc) is 6 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Rated frequency is 50 to 60 Hz, rated impulse withstand voltage (Uimp) is 4 kV, and operating ambient air temperature is -25 to 55 degrees C. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g.
- DS201 L C32 A30
The ABB DS201 L C32 A30 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 32 A, a rated residual current of 30 mA, Type A residual current, and C tripping characteristic. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity (Icu) is 6 kA, and rated conditional short-circuit current (Inc) is 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and operates from -25 to 55 °C.