- DS201 L C32 A30
The ABB DS201 L C32 A30 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 32 A, a rated residual current of 30 mA, Type A residual current, and C tripping characteristic. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity (Icu) is 6 kA, and rated conditional short-circuit current (Inc) is 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, measures 35 mm wide, 85 mm high, and 69 mm deep, and operates from -25 to 55 °C.
- DS201 L C32 A300
The ABB DS201 L C32 A300 is a 1P+N residual current circuit breaker with overcurrent protection, identified by manufacturer ID 2CSR245180R3324. It has a rated current of 32 A, rated residual current of 300 mA, Type A residual current, and C tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1, at 50 to 60 Hz. Rated ultimate short-circuit breaking capacity (Icu) is 6 kA; rated service short-circuit breaking capacity (Ics) is 4.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies 2 modular spacings, measures 35 mm wide by 85 mm high by 69 mm deep, and weighs 200 g. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles.
- DS201 L C32 AC30
The ABB DS201 L C32 AC30 is a 1P+N leakage protection circuit breaker with a rated current of 32 A and rated residual current of 30 mA. It has a type C tripping characteristic and type AC residual current. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated ultimate short-circuit breaking capacity is 6 kA; rated service short-circuit breaking capacity is 4.5 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, DIN-rail mounting, screw terminals, 35 mm width, 85 mm height, and 69 mm depth. Operating ambient air temperature is -25 to 55 degrees C. Degree of protection is IP20 and IP40.
- DS201 L C32 AC300
The ABB DS201 L C32 AC300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a rated current of 32 A, a rated residual current of 300 mA, Type AC residual current, and C tripping characteristic. Rated short-circuit capacity is 4.5 kA, with rated ultimate short-circuit breaking capacity (Icu) of 6 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage (Ui) is 500 V according to IEC/EN 60664-1. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies 2 modular spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail. Operating ambient air temperature is -25 to 55 °C.
- DS201 L C32 APR30
ABB DS201 L C32 APR30 is a 1P+N residual current circuit-breaker (RCBO) with a C tripping characteristic and Type A residual current. Rated current is 32 A, rated residual current 30 mA, rated operational voltage 240 V AC according to IEC 60898-1, and rated frequency 50 to 60 Hz. Rated short-circuit capacity is 4.5 kA, rated ultimate short-circuit breaking capacity 6 kA, and rated impulse withstand voltage 4 kV. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, 2 modular spacings, and mounts on DIN rail. Dimensions are 35 mm width, 85 mm height, 69 mm depth; net weight 200 g. Operating ambient air temperature is -25 to 55 °C.
- DS201 L C6 A10
The ABB DS201 L C6 A10 is a 1P+N residual current circuit breaker with a C tripping characteristic and Type A residual current detection. Rated current is 6 A and rated residual current is 10 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with rated insulation voltage 500 V according to IEC/EN 60664-1 and rated impulse withstand voltage 4 kV. Rated short-circuit capacity is 4.5 kA and rated ultimate short-circuit breaking capacity is 6 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device has two poles, one protected pole, two modular spacings, and DIN-rail mounting. Dimensions are 35 mm width, 85 mm height, and 69 mm depth, with 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 L C6 APR30
ABB DS201 L C6 APR30 is a DIN-rail leakage protection circuit breaker with a C tripping characteristic and Type A residual current detection. It is rated 6 A, 30 mA residual current, and 240 V AC according to IEC 60898-1, with 50 to 60 Hz rated frequency. Short-circuit ratings include 4.5 kA rated short-circuit capacity, 6 kA Icu, 6 kA Inc, and 4.5 kA Ics. It has one protected pole, two poles total, 2 modular spacings, and dimensions of 35 mm width, 85 mm height, and 69 mm depth. Standards cited are IEC/EN 61009-1 and IEC/EN 61009-2-1. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M B10 A100
ABB DS201 M B10 A100 is a 1P+N leakage protection circuit breaker (RCBO) with a B tripping characteristic, 10 A rated current, and 100 mA Type A rated residual current. It is rated 240 V AC according to IEC 60898-1, with 500 V rated insulation voltage according to IEC/EN 60664-1, 4 kV rated impulse withstand voltage, and 50 to 60 Hz rated frequency. Short-circuit ratings include 10 kA rated short-circuit capacity, 15 kA Icu and Inc, and 11.2 kA Ics. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, two modular spacings, screw terminals, DIN-rail mounting, IP20/IP40 protection, and an operating ambient air temperature range of -25 to 55 degrees C.