- DS201 M B16 AC100
ABB DS201 M B16 AC100 leakage protection circuit breaker with a B tripping characteristic and Type AC residual current. Rated current is 16 A and rated residual current is 100 mA. Rated operational voltage is 240 V according to IEC 60898-1. The device is rated 50 to 60 Hz and has a rated short-circuit capacity of 10 kA, rated ultimate short-circuit breaking capacity of 15 kA, and rated service short-circuit breaking capacity of 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It has two poles, one protected pole, DIN-rail mounting, screw terminals, IP20 protection, and dimensions of 35 mm width, 85 mm height, and 69 mm depth.
- DS201 M B16 AC30
ABB DS201 M B16 AC30 is a 1P+N leakage protection circuit breaker (RCBO) with B tripping characteristic and Type AC residual current. Rated current is 16 A; rated residual current is 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1; rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, has two poles, two modular spacings, screw terminals, and operates from -25 to 55 °C.
- DS201 M B16 F10
ABB DS201 M B16 F10 leakage protection circuit breaker, manufacturer ID 2CSR275580R0165. Two-pole device with one protected pole, rated current 16 A, rated residual current 10 mA, Type F residual current, and B tripping characteristic. Rated operational voltage 240 V AC according to IEC 60898-1; rated insulation voltage 500 V according to IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated frequency 50 to 60 Hz. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20 and IP40.
- DS201 M B16 F30
The ABB DS201 M B16 F30 is a 1P+N leakage protection circuit breaker with a rated current of 16 A and a rated residual current of 30 mA. It has a B tripping characteristic and Type F residual current detection. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated insulation voltage of 500 V according to IEC/EN 60664-1 and a rated impulse withstand voltage of 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It is rated 50 to 60 Hz and offers 10000 electrical cycles and 20000 mechanical cycles. It measures 35 mm wide, 85 mm high, and 69 mm deep, weighs 200 g, and mounts on DIN rail.
- DS201 M B20 A100
ABB DS201 M B20 A100 is a 1P+N residual current operated circuit breaker with overcurrent protection for single-phase circuits. It provides a rated current of 20 A, rated residual current of 100 mA, Type A residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. The device is rated 50 to 60 Hz, has two poles with one protected pole, and mounts on DIN rail. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1.
- DS201 M B20 A30
The ABB DS201 M B20 A30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current detection. It has a rated current of 20 A and a rated residual current of 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV and rated insulation voltage of 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 M B20 A30 110V
The ABB DS201 M B20 A30 110V is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A and 30 mA Type A residual current, tripping characteristic B. It has two poles, one protected pole, and occupies two DIN-rail modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1, with a test voltage of 110 V. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It is rated 50 to 60 Hz, with electrical endurance of 10000 cycles and mechanical endurance of 20000 cycles. Standards: IEC 61009-1 and IEC 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M B20 A300
ABB DS201 M B20 A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a B tripping characteristic, 20 A rated current, 300 mA Type A residual current, and 10 kA rated short-circuit capacity. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modules, measures 35 mm x 85 mm x 69 mm, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient temperature range is -25 to 55 °C. Degree of protection is IP20/IP40.