- DS201 M B20 A30
The ABB DS201 M B20 A30 is a 1P+N leakage protection circuit breaker with a B tripping characteristic and Type A residual current detection. It has a rated current of 20 A and a rated residual current of 30 mA. Rated operational voltage is 240 V AC according to IEC 60898-1, with a rated impulse withstand voltage of 4 kV and rated insulation voltage of 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. It mounts on DIN rail, occupies two modular spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and weighs 200 g.
- DS201 M B20 A30 110V
The ABB DS201 M B20 A30 110V is a 1P+N residual current circuit breaker with overcurrent protection, rated 20 A and 30 mA Type A residual current, tripping characteristic B. It has two poles, one protected pole, and occupies two DIN-rail modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1, with a test voltage of 110 V. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity 15 kA, and rated service short-circuit breaking capacity 11.2 kA. It is rated 50 to 60 Hz, with electrical endurance of 10000 cycles and mechanical endurance of 20000 cycles. Standards: IEC 61009-1 and IEC 61009-2-1. Dimensions are 35 mm width, 85 mm height, 69 mm depth, 200 g net weight. Operating ambient air temperature is -25 to 55 degrees C.
- DS201 M B20 A300
ABB DS201 M B20 A300 is a 1P+N residual current circuit breaker with overcurrent protection (RCBO) for single-phase circuits. It has a B tripping characteristic, 20 A rated current, 300 mA Type A residual current, and 10 kA rated short-circuit capacity. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. It complies with IEC/EN 61009-1 and IEC/EN 61009-2-1. The device occupies two DIN-rail modules, measures 35 mm x 85 mm x 69 mm, and weighs 200 g. Screw terminals accept conductors from 0.75 to 25 mm², with 2.8 N·m tightening torque. Operating ambient temperature range is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M B20 AC100
ABB DS201 M B20 AC100 is a DIN-rail leakage protection circuit breaker with overcurrent protection, Type AC residual current, B tripping characteristic, 20 A rated current, and 100 mA rated residual current. It has 1 protected pole, 2 poles, and 2 modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. Electrical endurance is 10000 cycles and mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20 and IP40. Net dimensions are 35 mm width, 85 mm height, and 69 mm depth; net weight is 200 g.
- DS201 M B20 AC30
ABB DS201 M B20 AC30 is a 1P+N leakage protection circuit breaker (RCBO) with B tripping characteristic and Type AC residual current. Rated current is 20 A; rated residual current is 30 mA. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated conditional short-circuit current (Inc) is 15 kA. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage (Ui) is 500 V according to IEC/EN 60664-1. Rated frequency is 50 to 60 Hz. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. It occupies two modular spacings, measures 35 mm wide, 85 mm high, and 69 mm deep, and mounts on DIN rail. Connecting capacity is 0.75 to 25 mm² stranded. Operating ambient air temperature is -25 to 55 °C. Degree of protection is IP20/IP40.
- DS201 M B20 AC300
ABB DS201 M B20 AC300 is a two-pole leakage protection circuit breaker with one protected pole, rated current 20 A and rated residual current 300 mA, Type AC. Tripping characteristic B. Rated operational voltage 240 V AC according to IEC 60898-1; rated insulation voltage 500 V according to IEC/EN 60664-1; rated impulse withstand voltage 4 kV; dielectric test voltage 2 kV. Rated short-circuit capacity 10 kA, rated ultimate short-circuit breaking capacity 15 kA, rated service short-circuit breaking capacity 11.2 kA, rated conditional short-circuit current 15 kA. Rated frequency 50 to 60 Hz. Standards: IEC/EN 61009-1 and IEC/EN 61009-2-1. Screw terminals, tightening torque 2.8 N·m, wire stripping length 12 mm. DIN-rail mounting, 2 modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature -25 to 55 °C. Degree of protection IP20, IP40.
- DS201 M B20 G30
ABB DS201 M B20 G30 is a DIN-rail leakage protection circuit breaker with a B tripping characteristic, Type A/G residual current, 20 A rated current, and 30 mA rated residual current. It is a two-pole device with one protected pole and occupies two modular spacings. Rated operational voltage is 240 V AC according to IEC 60898-1; rated insulation voltage is 500 V according to IEC/EN 60664-1, rated impulse withstand voltage is 4 kV, and rated frequency is 50 to 60 Hz. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity is 15 kA, and rated service short-circuit breaking capacity is 11.2 kA. Standards: IEC/EN 61009-1, IEC/EN 61009-2-1, OVE E 8601. Electrical endurance is 10000 cycles; mechanical endurance is 20000 cycles. Operating ambient air temperature is -25 to 55 degrees C. Dimensions are 35 mm width, 85 mm height, 69 mm depth; net weight 200 g.
- DS201 M B25 A100
ABB DS201 M B25 A100 is a 1P+N residual current breaker (RCBO) for single-phase circuits. It has a rated current of 25 A, rated residual current of 100 mA, Type A residual current, and B tripping characteristic. Rated operational voltage is 240 V AC according to IEC 60898-1; rated impulse withstand voltage is 4 kV. Rated short-circuit capacity is 10 kA, rated ultimate short-circuit breaking capacity (Icu) is 15 kA, and rated service short-circuit breaking capacity (Ics) is 11.2 kA. It conforms to IEC/EN 61009-1 and IEC/EN 61009-2-1. DIN-rail mounting, two modular spacings, 35 mm wide, 85 mm high, 69 mm deep, 200 g. Operating ambient air temperature is -25 to 55 °C. Screw terminals accept 0.75 to 25 mm² conductors; tightening torque is 2.8 N·m.